The Honeywell LG1093AA24, also cataloged as the LG1093AA24 Flame Sensor, operates as a dedicated hardware component for direct flame detection and signal monitoring within industrial burner management systems.

Hardware Specifications

Parameter Specification
Model LG1093AA24
Brand Honeywell
Origin USA / Global Manufacturing
Operating Temp Standard Industrial Flame Sensor Rating
Power Consumption System-powered via burner control interface
Cable Length 16 ft (4.9 m)
Core Technology Optical/Ultraviolet Flame Detection Element

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The LG1093AA24 flame sensing element converts targeted optical radiation emitted by combustion reactions into electrical telemetry for flame safeguard controllers. Sensor signal conditioning pathways interface with burner control modules to ensure immediate flame presence or flameout status verification.

Internal wiring and signal line paths utilize high-density insulation dielectric layers to maintain channel-to-channel isolation and prevent ground loop interference. Integrated noise suppression shields protect signal current transmission from industrial electromagnetic fields across the 16 ft (4.9 m) integral factory-terminated lead wire runs.

Frequently Asked Questions

Q: What is the factory lead cable length provided with the LG1093AA24 assembly?

A: The sensor includes an integral factory-installed connection cable measuring 16 ft (4.9 m) in length.

Q: How does the LG1093AA24 interface with central burner safeguard systems?

A: The device interfaces directly through dedicated signal wiring, delivering raw or conditioned flame current signals to compatible safety control cards.

Q: Can the sensor wiring lead be spliced or extended in the field?

A: Field splices are not recommended without proper high-temperature shielded junctions, as unshielded extensions introduce signal attenuation and electrical noise.

Field Installation Guidelines

  • Mount the sensor assembly securely on the sight pipe, ensuring a direct and unobstructed line of sight to the flame envelope.
  • Route the integral 16 ft (4.9 m) cable through dedicated metallic conduit separated from high-voltage ignition transformer leads to prevent inductive coupling.
  • Ground all conduit runs and enclosures according to local electrical codes, maintaining shield continuity up to the controller terminals.
  • Inspect optical viewing ports regularly for soot accumulation or physical damage to prevent signal degradation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more