Skip to content

What are you looking for?


You may also like

Honeywell 51305739-100 Experion PKS Cable AssemblyHoneywell 51305739-100 Experion PKS Cable AssemblyHoneywell 51305739-100 Experion PKS Cable Assembly
Honeywell 51305739-100 Experion PKS Cable Assembly
Honeywell 51305739-100 Experion PKS Cable Assembly
Honeywell 51305739-100 Experion PKS Cable Assembly

Honeywell 51305739-100 Experion PKS Cable Assembly


Only 10 left - Selling fast

PRODUCT SKU : 51305739-100

PRODUCT TYPE : Communication Cable Assemblies

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-integrity serial and network communication in Experion PKS and TDC 3000 platforms, the Honeywell 51305739-100 (51305739-100 Communication Cable Assembly) provides direct physical/electrical execution. It interconnects controller nodes, field I/O modules, and network interface units using shielded twisted-pair conductors to maintain differential signal transmission fidelity while mitigating electromagnetic noise injection within DCS control panels.

Hardware Specifications

Parameter Specification
Model 51305739-100
Brand Honeywell
Origin USA
Weight 0.5 kg
Dimensions 1-3 m customizable length
Operating Temp -20 to 60 deg C
Power Consumption Passive cabling component (0 W)
Assembly Type Communication Cable Assembly
Conductor Structure Shielded twisted-pair (STP)
Termination Type Honeywell proprietary industrial-grade connectors
Humidity Tolerance 5% to 95% RH (non-condensing)
System Compatibility Honeywell Experion PKS, TDC 3000 Systems

Channel-to-Channel Isolation & Loop Signal Protection

In distributed control system architectures, maintaining noise rejection and channel-to-channel isolation across inter-module buses is required to prevent data corruption. The shielded twisted-pair construction provides low attenuation and balanced differential signaling, preventing noise coupling from nearby high-voltage wiring. This shielding configuration prevents interference on adjacent 4-20 mA HART loop protocol connections and digital fieldbus networks routed through shared cabinet raceways.

Frequently Asked Questions

Q: Does the cable shield bond directly to chassis ground through the connector body?

A: Shield continuity is routed through the internal drain conductor to the metallic shell of the proprietary connector, establishing chassis grounding upon insertion into the module receptacle.

Q: Can this communication assembly be disconnected while the host system remains online?

A: Disconnection is supported only when redundant communication channels are active; breaking a non-redundant primary cable link will disrupt real-time I/O scanning and controller loop updates.

Field Installation Guidelines

  1. Power off non-redundant target controller cards or remote expansion racks before installing or replacing the cable assembly.
  2. Maintain a minimum static bending radius of 8 times the overall outer cable diameter during cabinet installation to preserve conductor impedance and foil shielding wrap integrity.
  3. Route the cable through dedicated low-voltage communication wireways, maintaining a physical clearance of at least 300 mm from AC power mains and motor drive conductors.
  4. Align the proprietary connector keyways with the chassis socket prior to applying axial force to prevent pin deformation.
  5. Secure all strain-relief screws or locking latches firmly to prevent connector loosening under operational plant vibration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more