Skip to content

What are you looking for?


You may also like

FS-SICC-0001/L24 Honeywell System Interconnection CableFS-SICC-0001/L24 Honeywell System Interconnection CableFS-SICC-0001/L24 Honeywell System Interconnection Cable
FS-SICC-0001/L24 Honeywell System Interconnection Cable
FS-SICC-0001/L24 Honeywell System Interconnection Cable
FS-SICC-0001/L24 Honeywell System Interconnection Cable

FS-SICC-0001/L24 Honeywell System Interconnection Cable


Only 10 left - Selling fast

PRODUCT SKU : FS-SICC-0001/L24

PRODUCT TYPE : System Interconnection Cables

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell FS-SICC-0001/L24, also cataloged as the FS-SICC-0001/L24 System Interconnection Cable, operates as a dedicated hardware component for high-integrity signal routing between I/O modules and Field Termination Assemblies (FTAs) within Honeywell Safety Manager platforms.

Hardware Specifications

Parameter Specification
Model FS-SICC-0001/L24
Brand Honeywell
Origin Netherlands
Weight Approx. 1 kg
Dimensions 24 m length, 9.93 mm outer diameter
Operating Temp -20 to 85 deg C
Power Consumption Passive interconnect assembly
Conductor Size 20 x AWG 22 (0.34 mm2)
Conductor Material Copper
Voltage Rating 300 V
Impedance 120 Ohms
Shielding Double shielded for EMI protection
Connectors Pre-terminated Honeywell-compatible connectors
Compliance RoHS compliant, UL listed

Channel-to-Channel Isolation and Loop Signal Integrity

The FS-SICC-0001/L24 interconnect cable maintains physical and electrical signal segregation across its 20 AWG 22 copper conductors when bridging Safety Manager subracks to termination units. Integrated double shielding limits electromagnetic interference (EMI) and prevents capacitive cross-talk from degrading sensitive 4-20 mA HART loop protocol signals. Combined with a 120 Ohm characteristic impedance match, the assembly preserves channel-to-channel isolation parameters and minimizes attenuation across long cabinet-to-cabinet routing runs.

Frequently Asked Questions

Q: What does the "L24" suffix represent in the module part number?

A: The "L24" suffix designates the factory-precut and pre-terminated overall cable length of 24 meters, optimized for fixed interconnect distances between control racks and field termination panels.

Q: How does the double shielding construction protect analog signal transmission?

A: The double shield layer provides continuous 360-degree EMI attenuation, shielding low-voltage loop signals against high-frequency industrial noise and cross-talk from adjacent wiring channels.

Q: Can the cable connectors be re-terminated in the field if cut to a shorter length?

A: Field cutting is not recommended as the cable is factory-assembled with molded, pre-tested Honeywell-compatible connectors designed to maintain grounding continuity and strain relief.

Field Installation Guidelines

  1. Inspect pre-terminated connector housings and pin contacts for contamination or mechanical distortion prior to engagement.
  2. Maintain the minimum dynamic bend radius during installation to prevent deformation of the outer thermoplastic jacket and shield layers.
  3. Align keyed connector housings with the target I/O module and FTA header sockets, pushing straight until the retaining latches click into place.
  4. Route the cable through dedicated low-voltage instrument ducts, maintaining isolation from high-voltage AC power lines and inverter cabling.
  5. Verify shield ground grounding continuity at the panel earth bus bar according to system grounding specifications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more