Product Details

Configured for slot isolation and airflow direction in Experion LX chassis, the Honeywell 51306344-101 (51306344 Filler Panel) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 51306344-101
Brand Honeywell
Base Model 51306344
Product Type Chassis Filler Panels
Panel Width 3.0 in (76.2 mm)
Construction Finish Corrosion-resistant powder coating
Origin USA
Weight Standard chassis panel weight
Dimensions 3.0 in slot cover dimensions
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive structural media
Humidity Rating 5-95% RH (non-condensing)
Vibration Rating 1.5 g at 10-150 Hz
System Compatibility Honeywell Experion LX Enclosures

Channel-to-Channel Isolation and Thermal Management

The 51306344-101 blanking panel seals unpopulated chassis slots adjacent to active I/O cards, field termination assemblies, and 4-20 mA HART loop protocol interface modules. By maintaining physical enclosure boundaries, it prevents internal air bypass and directs forced-convection cooling streams over active processor components. The durable powder-coated steel structure provides electromagnetic shielding continuity across open bay positions, suppressing cross-slot interference and protecting internal backplane buses from ambient dust particles, conductive debris, and thermal degradation.

Frequently Asked Questions

Q: What is the main functional purpose of installing the 51306344-101 filler panel in an active rack?

A: The panel seals unused chassis bays to direct forced cooling airflow across adjacent active modules, prevent particulate entry, and maintain structural shielding integrity.

Q: Can the 51306344-101 panel be installed or removed while the rest of the chassis is powered?

A: Yes, as a passive mechanical component with no electrical backplane connections, it can be mounted or unmounted without affecting system power or active controller operations.

Field Installation Guidelines

  • Safety Protocols: Verify that site cabinet safety procedures are observed prior to inserting tools or hardware into active chassis enclosures.
  • Chassis Alignment: Align the panel edges with the guide rails of the unpopulated Experion LX slot to ensure parallel fitment with adjacent active modules.
  • Hardware Fastening: Engage integrated mounting screws evenly into the chassis frame to establish a flush, vibration-resistant mechanical fit.
  • Thermal Verification: Confirm that all unpopulated slots retain full panel coverage to preserve internal cabinet pressure dynamics and forced-air cooling paths.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more