Product Details

The Honeywell 9007-006, also cataloged as the 9007 DMCS Communications Card Board, operates as a dedicated hardware component for multi-protocol serial and Ethernet data exchange within Series 9000 Controller networks. This interface board establishes deterministic data flow between the controller CPU and auxiliary industrial hardware, including computers and external field controllers. It integrates serial physical layers and network ports to execute serial-to-ethernet message conversion across industrial links.

Hardware Specifications

Parameter Specification
Model 9007-006
Brand Honeywell
Origin USA
Weight 0.56 kg (1.24 lbs)
Dimensions Standard Series 9000 slot card dimensions
Operating Temp 0 to 60 deg C
Power Consumption Standard backplane power allocation
Physical Interfaces 2x RS-232 ports, 1x RS-485 port, 1x Ethernet port
Protocol Support Modbus RTU, Modbus TCP/IP
System Compatibility Series 9000 Controllers with DMCS Option

4-20 mA HART Loop Protocol & DCS Connectivity

The Honeywell 9007-006 processes asynchronous serial and network streams while maintaining galvanic channel-to-channel isolation across the internal backplane bus interface. Designed for hybrid DCS control structures, the communications board routes digital values derived from 4-20 mA HART loop protocol concentrators and field devices into the main Series 9000 database. The hardware enforces signal filtering and buffer management on RS-232 and RS-485 interfaces to eliminate line noise and common-mode transient interference during continuous packet transmission.

Frequently Asked Questions

Q: Can the RS-232 and RS-485 ports on the 9007-006 operate simultaneously with Modbus RTU?

A: Yes, the onboard communication logic manages concurrent serial traffic across the dual RS-232 ports and the single RS-485 port without causing buffer overflow or frame collisions on the controller backplane.

Q: Is hot-swapping permitted for the 9007-006 card during controller operation?

A: Insertion or extraction of the communication card should only occur when the card rack slot is de-energized or set to a stopped state to prevent transient bus errors on the Series 9000 backplane.

Field Installation Guidelines

  • Verify that power to the controller rack is fully shut off before seating the 9007-006 card into the targeted Series 9000 backplane slot.
  • Use shielded twisted-pair (STP) cabling for all RS-485 connections and terminate the shield directly to protective earth at one end only.
  • Ensure all RS-232 cabling lengths do not exceed 15 meters (50 feet) to prevent baud rate attenuation and signal degradation.
  • Maintain clear physical separation between communication lines and high-voltage AC power wiring inside the panel wireways to suppress electromagnetic interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more