Skip to content

What are you looking for?


You may also like

Honeywell 900A16-0001 HC900 Series Analog Input ModuleHoneywell 900A16-0001 HC900 Series Analog Input ModuleHoneywell 900A16-0001 HC900 Series Analog Input Module
Honeywell 900A16-0001 HC900 Series Analog Input Module
Honeywell 900A16-0001 HC900 Series Analog Input Module
Honeywell 900A16-0001 HC900 Series Analog Input Module

Honeywell 900A16-0001 HC900 Series Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : 900A16-0001

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for 16-channel isolated signal acquisition in Honeywell Experion PKS and HC900 platforms, the Honeywell 900A16-0001 (900A16 Analog Input Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 900A16-0001
Brand Honeywell
Origin USA
Weight 0.397 kg
Dimensions 137 mm x 35.6 mm
Operating Temp -20 deg C to +60 deg C
Power Consumption 24 VDC nominal
Input Channels 16 isolated analog inputs
Signal Type 4-20 mA DC standard, configurable ranges
Input Resistance 250 ohms typical
Resolution 16-bit
Accuracy +/- 0.1 percent of span
Scan Rate Configurable, typically 10 ms/channel
Isolation Channel-to-channel and channel-to-bus
Storage Temp -40 deg C to +85 deg C
Humidity 5 percent to 95 percent RH, non-condensing
Diagnostics Signal quality validation, open-circuit detection

4-20 mA HART Loop & Channel-to-Channel Isolation

The 900A16-0001 module incorporates galavanic channel-to-channel and channel-to-bus isolation across all 16 analog inputs, preventing ground loops and common-mode potential differences from distorting process variable readings. Designed to interface directly with field instruments, the 250 ohm input resistance allows direct processing of 4-20 mA HART loop current signals. Integrated 16-bit analog-to-digital conversion combines with continuous channel diagnostics, providing real-time open-circuit detection and signal quality monitoring for critical process control loops.

Frequently Asked Questions

Q: How does channel-to-channel isolation benefit field instrumentation signals on the 900A16-0001?

A: Galvanic separation between individual channels prevents potential differences between grounded field transmitters from introducing measurement offsets or causing cross-channel interference.

Q: What diagnostic flags are generated by the module during sensor fault conditions?

A: The module executes real-time open-circuit detection and signal quality checks, asserting diagnostic alarms to the central controller when current loop values fall below standard operating thresholds.

Field Installation Guidelines

  1. Isolate loop power supplies before wiring field transmitters to the module terminal blocks to avoid overcurrent damage.
  2. Maintain individual twisted shielded pairs for each 4-20 mA loop, grounding the cable shield at a single point on the chassis earth terminal.
  3. Verify that terminal block screws are tightened to standard torque specifications to maintain solid low-resistance physical contacts.
  4. Ensure enclosure ambient conditions remain within -20 deg C to +60 deg C with non-condensing relative humidity below 95 percent.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more