Only 10 left - Selling fast

PRODUCT SKU : 900C52-0244-00

PRODUCT TYPE : CPU Processors

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 900C52-0244-00, also cataloged as the 900C52-0244-00 CPU Module, operates as a dedicated hardware component for real-time logic execution, field I/O synchronization, and network communications within Honeywell ControlEdge HC900 control system racks.

Hardware Specifications

Parameter Specification
Model 900C52-0244-00
Brand Honeywell
Origin USA
Operating Temp -40 to 70 deg C
Power Consumption 1.5 W
Voltage Range 0-10 VDC
Current Range 4-20 mA
Output Resolution 12 bits
Signal Update Time 500 microseconds
Galvanic Isolation 500 VDC

Channel-to-Channel Isolation and Analog Interface Execution

The Honeywell 900C52-0244-00 CPU module processes analog and discrete field telemetry with a deterministic cycle update time of 500 microseconds. Built-in signal handling supports standardized 0-10 VDC voltage and 4-20 mA HART loop protocol current ranges across connected I/O sub-assemblies at a 12-bit output resolution. The internal architecture features 500 VDC galvanic channel-to-channel isolation and backplane decoupling to prevent ground loop noise from corrupting logic program execution or analog signal processing pathways.

Frequently Asked Questions

Q: What precautions are necessary for the 500 VDC galvanic isolation boundary during field installation?

A: To maintain the 500 VDC isolation barrier, external loop power supplies and field instrument signal wiring must not share common grounding points prior to the module's isolation transformer stage.

Q: How does the 500-microsecond update time affect backplane I/O synchronization?

A: The 500-microsecond cycle ensures rapid instruction processing and memory refresh across the backplane bus, enabling fast dynamic feedback execution for critical control loops without latency buildup.

Q: Is hot-swapping supported for the 900C52-0244-00 CPU module?

A: Module insertion and removal under backplane power must comply with HC900 redundancy procedures. Hot-swapping a single non-redundant CPU will immediately halt system control execution.

Field Installation Guidelines

  1. De-energize the controller rack power supply before inserting the CPU module into the assigned rack slot unless operating within a validated redundant CPU configuration.
  2. Align the 900C52-0244-00 module board with the top and bottom chassis guides and push firmly until the backplane connector seats completely.
  3. Tighten the retaining screws at the top and bottom of the front bezel to ensure continuous chassis frame grounding and mechanical stability against vibration.
  4. Route 4-20 mA and 0-10 VDC signal cables in separate wiring trays spaced at least 200 mm away from AC power conductors.
  5. Ground all cable shielding at a single point on the local cabinet ground bar to mitigate ground loop interference.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more