Skip to content

What are you looking for?


You may also like

Honeywell 51202335-100 Series C Communication Cable ControllerHoneywell 51202335-100 Series C Communication Cable ControllerHoneywell 51202335-100 Series C Communication Cable Controller
Honeywell 51202335-100 Series C Communication Cable Controller
Honeywell 51202335-100 Series C Communication Cable Controller
Honeywell 51202335-100 Series C Communication Cable Controller

Honeywell 51202335-100 Series C Communication Cable Controller


Only 10 left - Selling fast

PRODUCT SKU : 51202335-100

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51202335-100, also cataloged as the 51202335-100 Communication Cable Controller, operates as a dedicated hardware component for serial data bus management and physical signal routing within Honeywell C300 and Series C systems. Designed to manage RS-485 network physical layers, the module accepts an operating voltage of 120 VAC at 60 Hz with a continuous current rating of 10 A. The unit is housed in an IP65 enclosure measuring 94 mm x 140 mm x 89 mm, processing differential RS-485 communication lines to execute multi-drop node synchronization across industrial controller backplanes.

Hardware Specifications

Parameter Specification
Model 51202325-100
Brand Honeywell
Origin USA
Weight 0.50 kg
Dimensions 94 mm x 140 mm x 89 mm
Operating Temp -40 to +70 deg C
Power Consumption 120 VAC, 60 Hz, 10 A current rating
Communication Interface RS-485 serial interface
Ingress Protection IP65
Storage Temp -55 to +85 deg C
System Platform Honeywell C300 / Series C Systems

4-20 mA HART Loop Protocol & Channel-to-Channel Isolation

The 51202335-100 incorporates optoelectronic line isolation between the high-power 120 VAC main supply rails and low-voltage RS-485 communication differential transceivers. When installed alongside analog instrument buses processing 4-20 mA HART loop protocol signals, the internal shielding suppresses common-mode voltage spikes and high-frequency noise. This isolation scheme preserves channel-to-channel isolation parameters and prevents ground potential differences across field cable runs from disturbing serial controller data transmission.

Frequently Asked Questions

Q: Can the RS-485 communication lines be connected or disconnected while the 120 VAC supply is active?

A: High-voltage wiring must be completely isolated before servicing terminals; however, the optically isolated RS-485 communication channels can be reconfigured if proper ground potential equalization is maintained.

Q: What termination impedance is required for the RS-485 bus managed by this cable controller?

A: Standard 120 ohm line-termination resistors should be applied at the physical end nodes of the RS-485 differential pair to prevent signal reflection across high-speed data runs.

Field Installation Guidelines

  1. Mount the IP65 enclosure securely onto the cabinet DIN-rail or mounting plate using the provided hardware points.
  2. Connect 120 VAC power leads to the designated power terminals, ensuring line, neutral, and frame earth conductors are wired correctly.
  3. Terminate RS-485 differential data cables using shielded twisted-pair conductors, bonding the cable shield braid to cabinet ground at a single point.
  4. Route high-voltage AC lines in separate wireways from RS-485 data paths to maintain signal fidelity and minimize noise coupling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more