TK-HAIO81 HART Honeywell Analog Output ModuleTK-HAIO81 HART Honeywell Analog Output ModuleTK-HAIO81 HART Honeywell Analog Output Module
TK-HAIO81 HART Honeywell Analog Output Module
TK-HAIO81 HART Honeywell Analog Output Module
TK-HAIO81 HART Honeywell Analog Output Module

TK-HAIO81 HART Honeywell Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : TK-HAIO81

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell TK-HAIO81 is an 8-channel high-precision analog output module designed for process control and automation. Featuring HART communication compliance (Revision 5.7), it delivers analog current signals to control valves and field actuators while enabling online device diagnostics and remote configuration.

Output Performance and Speed

The module provides eight output channels operating across a 0 to 21 mA signal range with a 15-bit resolution (656 nA/bit). It executes a scan time of 0-100% across all channels in 10 ms. For step response, current output reaches 95% of its final value in less than 23 ms without HART and less than 35 ms with HART enabled, while voltage output reaches 95% in less than 8.5 ms.

Protection and Stability

Built-in short-circuit protection safeguards individual outputs against wiring faults. Stability over operating temperature limits is defined by offset drift ratings of 50 uV/deg C for voltage and 200 nA/deg C for current, along with gain drift ratings of 20 ppm/deg C for voltage and 30 ppm/deg C for current. Robust RFI immunity restricts output signal error to less than 2.0% of range at 10 V/m across 27 to 1000 MHz.

Parameter Specification
Model TK-HAIO81
Brand Honeywell
Product Type HART Analog Output Module
Output Channels 8 analog outputs
Signal Range 0 to 21 mA
Resolution 15 bits (656 nA/bit)
HART Protocol Revision 5.7 compliance
Scan Time 0-100% for all channels in 10 ms
Current Output Settling Time (95% final value) <23 ms (without HART), <35 ms (with HART)
Voltage Output Settling Time (95% final value) <8.5 ms
Offset Drift 50 uV/deg C (Voltage), 200 nA/deg C (Current)
Gain Drift 20 ppm/deg C (Voltage), 30 ppm/deg C (Current)
Protection Short-circuit protection
RFI Immunity Error <2.0% of range at 10 V/m (27 to 1000 MHz)
Operating Temperature -20 deg C to +70 deg C
Dimensions 140 mm x 100 mm x 40 mm
Weight 0.5 kg

Frequently Asked Questions

Q: Does the TK-HAIO81 module support HART field instrument communications?

A: Yes, it complies with HART Protocol Revision 5.7 for digital instrument diagnostics and signal pass-through across all 8 channels.

Q: How does HART communication affect the current output response time?

A: Current output settling time to 95% of final value is less than 23 ms without HART, and increases to less than 35 ms when HART communication is active.

Q: What short-circuit protections are built into the TK-HAIO81?

A: The module includes onboard short-circuit protection to prevent hardware damage from improper field loop wiring or device short circuits.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more