Skip to content

What are you looking for?


You may also like

Honeywell TC-ODD321 Experion DC Output ModuleHoneywell TC-ODD321 Experion DC Output ModuleHoneywell TC-ODD321 Experion DC Output Module
Honeywell TC-ODD321 Experion DC Output Module
Honeywell TC-ODD321 Experion DC Output Module
Honeywell TC-ODD321 Experion DC Output Module

Honeywell TC-ODD321 Experion DC Output Module


Only 10 left - Selling fast

PRODUCT SKU : TC-ODD321

PRODUCT TYPE : Digital Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell TC-ODD321 is a high-density 32-channel digital DC output module designed for use within the Honeywell Experion PKS system architecture. It distributes discrete control signals across 32 individual channels grouped into two isolated banks of 16 points per common terminal. Operating within a flexible 10 VDC to 31.2 VDC range, the unit connects to field actuators via a 36-position TC-TBCH terminal block.

Channel Grouping and Voltage Derating

The 32 channels are arranged into two groups of 16 outputs, with each group sharing a dedicated common return path. The operational output voltage depends on ambient temperature limits, supporting up to 31.2 VDC at 50 deg C with linear derating down to a maximum of 28 VDC at 60 deg C. Each output requires a minimum on-state load current of 3.0 mA to ensure reliable switching.

Electrical Output and Transient Tolerance

Under full load, the module maintains a maximum on-state voltage drop of 1 VDC at rated current per point, or up to 3 VDC under IEC 1131-2 compliance conditions. For inductive or high-inrush loads, each channel tolerates a surge current of up to 1 A for 10 ms duration, repeatable every 2 seconds at an ambient temperature of 60 deg C. Total module power dissipation is rated at 6.1 W.

Parameter Specification
Model TC-ODD321
Brand Honeywell
Product Type Experion DC Output Module
Number of Outputs 32 channels (16 points per common)
Output Voltage Range 10 VDC to 31.2 VDC @ 50 deg C (linear derating); 10 VDC to 28 VDC @ 60 deg C
Minimum On-State Load Current 3.0 mA per output
Maximum On-State Voltage Drop 1 VDC @ rated current per point (3 VDC for IEC 1131-2)
Surge Current 1 A for 10 ms (repeatable every 2 s @ 60 deg C)
Power Dissipation 6.1 W
Terminal Block Connection TC-TBCH (36-position)
Shipping Weight 1.5 kg

Frequently Asked Questions

Q: What terminal block is required for field wiring on the Honeywell TC-ODD321?

A: The module requires the TC-TBCH 36-position terminal block for field wiring connections.

Q: How are the 32 output channels grouped on this module?

A: The 32 output channels are structured into two isolated banks, with 16 output points sharing a common connection per bank.

Q: What are the thermal derating conditions for the output voltage?

A: The module operates from 10 VDC to 31.2 VDC up to 50 deg C, with linear derating reducing the maximum voltage to 28 VDC at 60 deg C.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more