Product Details

The Honeywell TC-FPDXX2 is an uncoated Series-A standard power supply module designed to deliver stable system power within industrial automation chassis architectures. It accepts an input voltage range of 19.2 to 32 VDC and provides a maximum total power output of 70 W at 60 deg C.

Power Distribution and Backplane Outputs

The module supplies multiple DC rails to support chassis backplane requirements, delivering up to 1.5 A at 1.2 V, 4 A at 3.3 V, 10 A at 5.1 V, and 2.8 A at 24.0 V. It handles an input power rating of 100 W with a maximum inrush current of 30 A. Internal circuit protection is provided by a soldered, non-replaceable fuse.

Chassis Installation and Physical Dimensions

Designed to mount on the left side of the chassis, the unit does not consume an active I/O or controller slot. It accommodates #14 AWG (1.4 mm) wiring connections, measures 11.2 x 14.5 x 14.0 cm, and has a net product weight of 1.1 kg.

Parameter Specification
Model TC-FPDXX2
Brand Honeywell
Product Type Standard Power Supply Module
Series Uncoated Series-A
Input Voltage Range 19.2 to 32 VDC
Input Power 100 W
Maximum Inrush Current 30 A
Frequency Range DC
Total Power Output Maximum 70 W @ 60 deg C
Backplane Output Current Maximum 1.5 A @ 1.2 V, 4 A @ 3.3 V, 10 A @ 5.1 V, 2.8 A @ 24.0 V
Fuse Protection Non-replaceable fuse soldered in place
Wiring #14 AWG (1.4 mm)
Chassis Location Left side of chassis (does not consume a slot)
Dimensions (L x D x H) 11.2 x 14.5 x 14.0 cm (4.41 x 5.71 x 5.51 in)
Weight 1.1 kg
Shipping Weight 2.5 kg

Frequently Asked Questions

Q: Does the TC-FPDXX2 module consume an active slot in the chassis?

A: No, the power supply mounts on the left side of the chassis and does not consume a standard slot.

Q: What are the backplane current outputs supported by this power supply?

A: It delivers up to 1.5 A at 1.2 V, 4 A at 3.3 V, 10 A at 5.1 V, and 2.8 A at 24.0 V.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more