Skip to content

What are you looking for?


You may also like

PanelView Plus 6 Compact Touch Terminal Allen-Bradley 2711PC-T6M20D8PanelView Plus 6 Compact Touch Terminal Allen-Bradley 2711PC-T6M20D8PanelView Plus 6 Compact Touch Terminal Allen-Bradley 2711PC-T6M20D8
PanelView Plus 6 Compact Touch Terminal Allen-Bradley 2711PC-T6M20D8
PanelView Plus 6 Compact Touch Terminal Allen-Bradley 2711PC-T6M20D8
PanelView Plus 6 Compact Touch Terminal Allen-Bradley 2711PC-T6M20D8

PanelView Plus 6 Compact Touch Terminal Allen-Bradley 2711PC-T6M20D8


Only 10 left - Selling fast

PRODUCT SKU : 2711PC-T6M20D8

PRODUCT TYPE : PanelView

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 2711PC-T6M20D8 belongs to the PanelView Plus 6 Compact series, offering reliable operator interface control for compact industrial systems. It combines a resistive touchscreen, multiple communication options, and a durable grayscale display for use in various automation environments.

Technical Specifications

  • Manufacturer Allen-Bradley (Rockwell Automation)

  • Product Line PanelView Plus 6 Compact

  • Model / Part Number 2711PC-T6M20D8

  • Product Type Compact Operator Terminal

  • Display Size 5.7 inches (145 mm)

  • Display Type Monochrome TFT LCD (Grayscale)

  • Display Area 115 x 86 mm (4.5 x 3.4 inches)

  • Resolution 320 x 240 pixels (QVGA)

  • Touchscreen Type Analog resistive

  • Backlight White LED, non-replaceable, rated for 25,000 hours at 25°C (77°F)

  • Internal Memory 256 MB RAM and 512 MB nonvolatile memory (approx. 79 MB available for user applications)

  • Communication Ports Ethernet, RS-232 serial port, and two USB host ports

  • Input Voltage Range 18–32 VDC

  • Nominal Input Power 24 VDC

  • Display Color Depth 18-bit grayscale

  • Input Method Touchscreen

  • Weight 2.06 lbs (0.94 kg)

  • Lifecycle Status End of Life

Key Features

  • Compact operator terminal designed for space-limited control systems

  • Reliable LED backlight with long service life and low power consumption

  • Integrated Ethernet and serial interfaces for versatile connectivity

  • USB host support for data backup and external device integration

  • Industrial-grade construction for dependable operation in harsh environments

Application Scenarios

The Allen-Bradley 2711PC-T6M20D8 is ideal for:

  • Machine-level operator control panels

  • OEM and small-scale automation equipment

  • Replacement of older PanelView models

  • Distributed control systems requiring Ethernet or RS-232 communication

Similar Models Comparison

  • 2711PC-T6M20D8 – 5.7" grayscale TFT LCD, 512 MB memory, end-of-life model

  • 2711PC-T6M20D8A – 5.7" color TFT display, same memory, active model

  • 2711PC-T10C4D8 – 10.4" color TFT display, larger screen area, active model

FAQs

Q: Is the LED backlight replaceable?
A: No, it is a sealed unit, but rated for long lifespan (25,000 hours minimum).

Q: Can it communicate directly with CompactLogix or MicroLogix PLCs?
A: Yes, it supports Ethernet and RS-232 communication for direct PLC integration.

Q: Does it support USB peripherals?
A: Yes, the unit includes two USB host ports for data transfer and external device connection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more