Description

The 2711P-T10C15A1 is a ruggedized operator interface designed for sophisticated visualization in industrial automation. Featuring a 10.4-inch high-resolution display, this terminal serves as a primary control node for machinery and process monitoring. Unlike basic HMI units, this specific configuration is equipped with built-in ControlNet communication, offering deterministic data exchange alongside standard Ethernet and Serial interfaces. It utilizes a modular design that allows for the independent maintenance of the logic module and the display assembly, ensuring long-term serviceability.

Technical Specifications

  • Display Technology: 10.4-inch Color Active Matrix TFT

  • Resolution and Color: 640 x 480 VGA; 18-bit color depth

  • Operator Input: Analog resistive touchscreen

  • System Memory: 64 MB RAM

  • Application Storage: 64 MB Internal Flash memory

  • Network Interfaces: One (1) ControlNet port; One (1) 10/100 Ethernet port

  • Peripheral Comms: One (1) RS-232 Serial port; Two (2) USB 1.1 Host ports

  • Power Requirements: 18...32V DC (24V DC nominal)

  • Energy Consumption: 70 W maximum (2.9 A at 24V DC)

  • Thermal Range: 0 to 55 °C (32 to 131 °F)

  • Physical Dimensions: 248 x 329 x 55 mm (9.77 x 12.97 x 2.18 in)

  • Net Weight: 2.6 kg (5.7 lbs)

  • Software Support: Fully compatible with FactoryTalk View Machine Edition (ME) Studio

Hardware Versatility and Performance

The 2711P-T10C15A1 excels in environments requiring reliable remote I/O interaction. The integration of ControlNet makes it a preferred choice for large-scale manufacturing lines where HMI response timing must be synchronized with high-speed control tasks. Furthermore, the dual USB ports simplify maintenance by allowing for external mouse/keyboard input and localized project transfers via removable storage drives.

HMI Maintenance FAQ

  • Is it possible to replace the screen without losing the logic configuration?Yes, the 2711P-T10C15A1 is built on a modular architecture. You can detach the logic module from the rear of the display to perform hardware swaps while preserving your application data.

  • Does this unit support external memory expansion?The terminal includes a dedicated CompactFlash slot that can be used to increase application storage or for automated data logging and recipe management.

  • What is the difference between the 'A1' and 'D1' suffix?The 2711P-T10C15A1 is specifically configured for AC power input via an integrated power supply, whereas 'D1' versions are strictly DC-powered. Note: Ensure your local power matches the terminal's rating before installation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more