Skip to content

What are you looking for?


You may also like

Allen-Bradley 2711C-T6M PanelView Component C600 Monochrome Touch TerminalAllen-Bradley 2711C-T6M PanelView Component C600 Monochrome Touch TerminalAllen-Bradley 2711C-T6M PanelView Component C600 Monochrome Touch Terminal
Allen-Bradley 2711C-T6M PanelView Component C600 Monochrome Touch Terminal
Allen-Bradley 2711C-T6M PanelView Component C600 Monochrome Touch Terminal
Allen-Bradley 2711C-T6M PanelView Component C600 Monochrome Touch Terminal

Allen-Bradley 2711C-T6M PanelView Component C600 Monochrome Touch Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711C-T6M

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 2711C-T6M is a compact and user-friendly operator terminal from the PanelView Component C600 series. Designed for simple machine-level control and monitoring, it offers reliable touchscreen operation, versatile communication options, and a monochrome LCD display suitable for cost-effective industrial applications.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: PanelView Component Series

  • Part Number: 2711C-T6M

  • Display Type: Color transmissive CSTN passive matrix LCD

  • Display Size: 6 inches

  • Display Area: 115 x 86 mm (4.53 x 3.39 in.)

  • Resolution: 320 x 240 pixels (QVGA)

  • Display Color: Monochrome

  • Input Type: Touchscreen (analog resistive)

  • Touchscreen Actuation: Rated for 1 million presses

  • Backlight: 50,000 hours minimum life (non-replaceable)

  • Input Voltage Range: 18–30V DC (24V DC nominal)

  • Heat Dissipation: 32 BTU/hr

  • Communication Ports:

    • RS-232 (DH-485)

    • RS-232 (DF1)

    • RS-485 (supports Modbus and Siemens MPI)

    • USB port for programming and data transfer

  • Supported Web Browsers: Internet Explorer 7/8, Firefox 3.0

  • Weight: 2.06 lbs (0.94 kg)

  • Product Lifecycle Status: Discontinued/Obsolete

Key Features

  • Compact Design: Ideal for space-limited panels and standalone equipment.

  • Multi-Protocol Communication: Compatible with Modbus, Siemens MPI, and Allen-Bradley DH-485 protocols.

  • Durable Touchscreen: Long-life analog touch panel rated for one million actuations.

  • Integrated USB Support: Enables file transfer, configuration, and firmware updates.

  • Low Power Operation: Runs efficiently on 24V DC with minimal heat output.

  • Browser Accessibility: Supports configuration via web browsers for simplified setup and maintenance.

Application Scenarios

  • Machine-Level Control: Provides operator interface for compact manufacturing machines.

  • OEM Equipment: Suitable for integration into small automation panels.

  • System Monitoring: Displays status and diagnostic data for local processes.

  • Training and Demonstration Panels: Useful for educational or test bench applications.

FAQs

Q: What is the screen size of the 2711C-T6M?
A: The terminal features a 6-inch monochrome CSTN LCD display.

Q: Which communication protocols are supported?
A: The unit supports DH-485, DF1, Modbus, and Siemens MPI communication.

Q: Is the touchscreen field replaceable?
A: No, the analog touchscreen and backlight are not replaceable components.

Q: Can it be configured via web browser?
A: Yes, it supports Internet Explorer and Firefox browser-based configuration.

Q: What is the input voltage range?
A: The terminal operates between 18V DC and 30V DC, with a nominal rating of 24V DC.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more