Product Details

Overview

The Allen-Bradley 2711-B5A5 is a PanelView 550 standard operator terminal with a monochrome LCD in blue mode. It is designed to provide reliable operator interface capabilities for SLC and PLC systems, enabling display, input, and control of machine and process data. The terminal supports both keypad and touch input for flexible operation. Although now discontinued, it remains a robust choice for legacy applications.

Key Features

  • 5.5-inch monochrome LCD display with blue mode

  • Touchscreen with 128 touch cells, rated for 1 million presses

  • 10 function keys (F1–F10) for direct operator input

  • Application memory: 170 KB runtime memory, 240 KB non-volatile storage for objects, text, and bitmaps

  • Dual communication support via DH485 and RS-232 (DF1)

  • LED backlight with a rated life of 100,000 hours

  • Input voltage range: 85–264V AC, 47–63 Hz

  • Accessories: function key legend inserts, anti-glare overlays, backlight replacements, real-time clock replacements, mounting hardware, interface modules, and power supply components

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: PanelView 550

  • Part Number: 2711-B5A5

  • Weight: 2.50 lbs (1.13 kg)

  • Display Type: Monochrome LCD (blue mode)

  • Display Area: 120 x 60 mm (4.75 x 2.38 in)

  • Resolution: 256 x 128

  • Touchscreen: 128 cells, 1 million actuations

  • Keypad: 10 function keys

  • Memory: 170 KB runtime, 240 KB non-volatile

  • Communication Ports: DH485, RS-232 (DF1)

  • Input Voltage: 120V AC (operating 85–264V AC, 47–63 Hz)

  • Series Compatibility: A–H

  • Product Lifecycle Status: Discontinued

Application Scenarios

The 2711-B5A5 terminal is suited for:

  • Displaying and controlling process variables in legacy PLC systems

  • Operator interfaces for assembly lines, packaging, and material handling

  • Integration with PLCs requiring monochrome or simple graphical displays

  • Applications where a compact 5.5-inch display is sufficient

FAQs

Q: Can this terminal connect to modern PLC systems?
A: It is compatible with PLCs that support DH485 or RS-232 DF1 protocols, primarily older SLC and PLC-5 systems.

Q: How durable is the touchscreen?
A: The touch interface supports up to 1 million actuations and is designed for industrial environments.

Q: Are replacement parts available for discontinued models?
A: Accessories like function key legends, backlight replacements, and interface modules are still available from authorized distributors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more