Skip to content

What are you looking for?


You may also like

ABB DIS0012 2RCA025340A0001M LHMI Front PanelABB DIS0012 2RCA025340A0001M LHMI Front PanelABB DIS0012 2RCA025340A0001M LHMI Front Panel
ABB DIS0012 2RCA025340A0001M LHMI Front Panel
ABB DIS0012 2RCA025340A0001M LHMI Front Panel
ABB DIS0012 2RCA025340A0001M LHMI Front Panel

ABB DIS0012 2RCA025340A0001M LHMI Front Panel


Only 10 left - Selling fast

PRODUCT SKU : DIS0012 2RCA025340A0001M

PRODUCT TYPE : Front Panels

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for structural housing enclosure execution in industrial control platforms, the ABB DIS0012 2RCA025340A0001M (DIS0012 Front Panel) provides direct physical/electrical execution. The aluminium front panel assembly serves as a protective front fascia and mechanical interface, isolating internal LHMI display electronics and circuit assemblies from environmental contaminants and mechanical stress within cabinet cutouts.

Hardware Specifications

Parameter Specification
Model DIS0012 2RCA025340A0001M
Brand ABB
Series LHMI Aluminium Front Series
Material Anodized Aluminium
Dimensions 12.6 cm x 12.4 cm x 2.2 cm
Weight 0.78 kg
Operating Temp -20 deg C to +65 deg C
Power Consumption Passive mechanical component (0 W)
System Compatibility ABB Relion Protection Relays / LHMI Units
Origin Global Manufacturing Facilities

Deterministic Network Routing & I/O Density Scaling

The structural enclosure framework supports backplane bus communication velocity and deterministic network architecture by providing rigid physical containment for underlying control electronics. The precision-machined aluminium chassis supports target I/O density scaling and alignment, preventing mechanical strain on internal connectors during rack insertion. Electrostatic discharge (ESD) protection and stray field mitigation are maintained via conductive ground path continuity across the panel framework.

Frequently Asked Questions

Q: Does the DIS0012 2RCA025340A0001M require internal wiring or power connections?

A: No. The front panel functions purely as a passive physical housing and structural fascia component, drawing 0 W of electrical power.

Q: How does the panel maintain EMI protection for underlying display electronics?

A: The metal construction forms a continuous conductive barrier that routes high-frequency surface currents to cabinet frame ground when fastened with conductive screws.

Q: Can the front panel be hot-swapped while the host relay or controller is powered?

A: Physical removal of the panel requires unfastening enclosure hardware; power to the host device should be isolated to prevent accidental contact with internal live components.

Field Installation Guidelines

Observe the following field procedures during panel assembly and chassis integration:

  1. Inspection: Inspect the aluminium front panel for mechanical deformation, thread damage, or surface scratches before panel mounting.
  2. Frame Alignment: Align the panel housing flush against the sub-rack or door cutout mounting holes, ensuring internal gaskets sit flat against the panel perimeter.
  3. Fastener Torque: Insert retaining screws and tighten in a cross-pattern to 0.8 N-m to ensure uniform compression and mechanical stability under industrial vibration.
  4. Ground Validation: Verify low-resistance bonding continuity between the panel chassis and the protective earthing (PE) bus using a low-resistance ohmmeter.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more