Skip to content

What are you looking for?


You may also like

2711P-T15C4D1 | Allen-Bradley | PanelView Plus 1500 HMI Terminal2711P-T15C4D1 | Allen-Bradley | PanelView Plus 1500 HMI Terminal2711P-T15C4D1 | Allen-Bradley | PanelView Plus 1500 HMI Terminal
2711P-T15C4D1 | Allen-Bradley | PanelView Plus 1500 HMI Terminal
2711P-T15C4D1 | Allen-Bradley | PanelView Plus 1500 HMI Terminal
2711P-T15C4D1 | Allen-Bradley | PanelView Plus 1500 HMI Terminal

2711P-T15C4D1 | Allen-Bradley | PanelView Plus 1500 HMI Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-T15C4D1

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 2711P-T15C4D1 by Allen-Bradley is a PanelView Plus 1500 operator terminal featuring a 15-inch color TFT LCD touchscreen. This unit is designed for industrial HMI applications, offering robust performance and reliable operation for discontinued or legacy systems. It supports multiple communication protocols and provides a high-resolution interface for efficient control and monitoring.

Technical Specifications

  • Model: 2711P-T15C4D1

  • Manufacturer: Allen-Bradley

  • Product Type: PanelView Plus 1500 Operator Terminal

  • Display: 15.0-inch TFT LCD, color active matrix

  • Display Area: 304 x 228 mm (12.0 x 9.0 in.)

  • Resolution: 1024 x 768

  • Backlight: CCFL, minimum 50,000 hours

  • Touchscreen Durability: 1 million actuations, 10–110 g actuation force

  • Memory: 64MB Flash, 64MB RAM

  • Communication Ports: Ethernet, Data Highway Plus (DH+), Remote I/O (RIO), DH485, RS232, USB

  • Power Input: 18–32 VDC

  • Integrated Modules: Logic Module: 2711P-RP1; Display Module: 2711P-RDT15C; CompactFlash Card: 2711P-RW1 (32MB)

  • Weight: 9.44 lbs (4.28 kg)

  • Lifecycle Status: Discontinued

Features

  • Durable touchscreen with high-resolution display

  • Supports multiple Allen-Bradley communication protocols

  • Factory-configured memory modules for seamless operation

  • Ideal for retrofitting discontinued PanelView systems

Applications

The 2711P-T15C4D1 is suitable for industrial operator control panels, monitoring systems, and integration into existing PanelView Plus 1500 setups where reliable visual feedback and touch input are required.

FAQ

Q: Can this terminal still be integrated with modern ControlLogix systems?
A: Yes, it supports Ethernet and standard Allen-Bradley communication protocols for integration.

Q: What is the expected backlight lifespan?
A: The CCFL backlight has a minimum rated life of 50,000 hours.

Q: Is this unit new or used?
A: This listing is for a used unit in very good condition (VGC).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more