Skip to content

What are you looking for?


You may also like

2711P-B7C22D9P | Allen-Bradley | PanelView Plus 7 Performance Touch/Keypad Terminal2711P-B7C22D9P | Allen-Bradley | PanelView Plus 7 Performance Touch/Keypad Terminal2711P-B7C22D9P | Allen-Bradley | PanelView Plus 7 Performance Touch/Keypad Terminal
2711P-B7C22D9P | Allen-Bradley | PanelView Plus 7 Performance Touch/Keypad Terminal
2711P-B7C22D9P | Allen-Bradley | PanelView Plus 7 Performance Touch/Keypad Terminal
2711P-B7C22D9P | Allen-Bradley | PanelView Plus 7 Performance Touch/Keypad Terminal

2711P-B7C22D9P | Allen-Bradley | PanelView Plus 7 Performance Touch/Keypad Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-B7C22D9P

PRODUCT TYPE : Graphic Terminals

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 2711P-B7C22D9P is a high-tier operator interface from the Allen-Bradley PanelView Plus 7 Performance series, featuring a dual-input design that combines an analog resistive touchscreen with a physical keypad. This 6.5-inch widescreen terminal is optimized for complex monitoring environments, utilizing a vibrant TFT color active-matrix display with VGA resolution. Designed for modern network architectures, the 2711P-B7C22D9P (UPC 885630844503) includes dual Ethernet ports that support Device Level Ring (DLR) topologies, significantly increasing network resiliency. With 1GB of RAM and a robust Windows-based execution environment, it handles high-density data logging and complex faceplates with minimal latency.

Technical Specifications

  • Series: PanelView Plus 7 Performance

  • Model Number: 2711P-B7C22D9P

  • Display: 6.5-inch Color Active-Matrix TFT

  • Resolution: 640 x 480 VGA; 18-bit Graphics

  • Operator Input: Analog Resistive Touch and Stainless Steel Keypad

  • Processor Memory: 1GB RAM; 512MB Non-volatile storage (approx. 80MB User Space)

  • Network Connectivity: Dual 10/100Base-T Ethernet ports (Supports DLR)

  • Peripheral Interfaces: 3 USB Host ports (Type A); 1 USB Device port (Type B)

  • Input Voltage: 18 to 30V DC (24V DC Nominal)

  • Power Demand: 50W maximum consumption

  • Backlight Integrity: White LED (non-replaceable); 50,000 hours life span

  • Software Environment: FactoryTalk View Machine Edition (ME)

Implementation and Network Strategy

The 2711P-B7C22D9P is particularly effective in washdown environments or applications where operators wear heavy gloves, as the physical keypad provides tactile feedback that touchscreens alone cannot offer. Unlike the Standard series, this Performance model allows for more than 25 screens and 200 alarms, making it suitable for plant-wide control integration. The integrated DLR capability allows the terminal to remain operational even if a single point in the Ethernet ring fails, ensuring continuous visualization for critical processes.

FAQ

What is the advantage of the dual-input "B" configuration?The "B" in 2711P-B7C22D9P denotes "Both" (Touch and Keypad). This provides redundancy and accessibility; if the touchscreen surface is damaged or if the operator is in a high-vibration environment, the physical keys ensure the machine can still be safely controlled.

Does this terminal support SD cards for data logging?Yes, it features a dedicated Secure Digital (SD) card slot for external storage, allowing for easy firmware upgrades and historical data log retrieval.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more