Skip to content

What are you looking for?


You may also like

HIMA H51q System F 8650A Central Processing Module (CPM)HIMA H51q System F 8650A Central Processing Module (CPM)HIMA H51q System F 8650A Central Processing Module (CPM)
HIMA H51q System F 8650A Central Processing Module (CPM)
HIMA H51q System F 8650A Central Processing Module (CPM)
HIMA H51q System F 8650A Central Processing Module (CPM)

HIMA H51q System F 8650A Central Processing Module (CPM)


Only 10 left - Selling fast

PRODUCT SKU : F8650A

PRODUCT TYPE : Central Processing Module

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Architecture Overview

The F 8650A serves as the high-integrity central processing unit for HIMA PES H51q-MS, HS, and HRS safety systems. Engineered to meet rigorous safety standards (AK 1-6 and SIL 3), this module utilizes a redundant microprocessor architecture to ensure fail-safe operation in critical process environments. It manages logic execution, system diagnostics, and communication protocols across the backplane, providing the computational foundation for emergency shutdown and fire and gas applications.

Detailed Hardware Specifications

  • Model Identification: F 8650A

  • Processor Architecture: Dual INTEL 386EX 32-bit microprocessors

  • System Clock Speed: 25 MHz

  • Firmware Memory: 1 MB Flash-EPROM for Operating System storage

  • Application Memory: 512 KB Flash-EPROM for user-defined safety programs

  • Volatile Data Storage: 256 KB SRAM for real-time variables and stack operations

  • Communication Ports: Dual RS 485 serial interfaces for peripheral connectivity

  • Integrated Diagnostics: 4-digit alphanumeric matrix display for real-time status and error codes

  • Safety Mechanism: Hardware-based fail-safe watchdog for autonomous error switch-off

  • Watchdog Output: 24 VDC output, 500 mA rated capacity, short-circuit protected

  • System Compatibility: Optimized for H51q-MS, H51q-HS, and H51q-HRS safety racks

  • Safety Integrity Level: Certified for use in safety-related requirements up to AK 6 / SIL 3

Safety Logic and Diagnostic Functionality

The F 8650A is designed with a 1-out-of-2 (1oo2) or 2-out-of-4 (2oo4) internal voting structure depending on the system configuration. The onboard matrix display provides engineers with immediate site diagnostics without requiring external software for basic troubleshooting. If a critical internal fault is detected, the fail-safe watchdog immediately de-energizes the safety-related outputs to bring the process to a predefined safe state.

Technical FAQ

What is the function of the watchdog output on the F 8650A?The 24 VDC watchdog output is used to signal the healthy status of the CPU to external monitoring devices or to power safety relays. If the F 8650A detects a hardware discrepancy, this output drops to 0V.

Can the user program be modified while the system is online?Modifications depend on the specific H51q system redundancy level. In HRS (High Redundancy) configurations, the F 8650A supports specialized reload procedures to maintain safety integrity during updates.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more