PRODUCT SKU : F60DIO24/1601

PRODUCT TYPE : Digital I/O Module

PRODUCT VENDOR : Hima


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Technical Overview

The F60 DIO 24/16 01 is a high-density safety-related I/O component engineered for the HIMatrix F60 system. This module provides a robust interface for 24 digital inputs and 16 digital outputs within a compact 4HP form factor, specifically designed for applications requiring up to SIL 3 safety integrity. Its architecture features comprehensive galvanic isolation to maintain signal purity and protect the central processing unit from field-side electrical interference.

Detailed Specifications

  • Model Number: F60 DIO 24/16 01

  • Part Number: 984420102

  • Module Type: Integrated Digital Input/Output (24 IN / 16 OUT)

  • Operating Voltage Range: 24 VDC (-15% to +20%)

  • Internal Current Consumption: 380 mA at 24 VDC / 150 mA at 3.3 VDC

  • Input Configuration: 24 Channels, Galvanically Isolated

  • High Level Logic Threshold: 10 VDC to 30 VDC (Nominal 24 VDC)

  • Low Level Logic Threshold: 0 VDC to 5 VDC

  • Input Current Draw: 2 mA at 10V up to 5 mA at 24V

  • Switching Point Sensitivity: Typical 7.5 V

  • Output Configuration: 16 Channels, Galvanically Isolated

  • Output Voltage Delivery: 18.4 VDC to 26.8 VDC

  • Internal Voltage Drop: Maximum 2V at 2A load

  • Sensor Supply Capacity: 3 channels providing 20 V / 100 mA each (Short-circuit protected)

  • Form Factor: 6 RU height, 4 HP width

  • Unit Weight: 260 g

  • Thermal Limits: 0°C to +60°C operating / -40°C to +85°C storage

Application and Diagnostics

The F60 DIO 24/16 01 is frequently deployed in emergency shutdown (ESD) systems and fire and gas (F&G) logic solvers. It utilizes internal self-testing routines to ensure fault detection in real-time. The integrated sensor power outputs simplify the wiring of field devices such as dry contacts or proximity switches by providing supervised 20V power directly from the module.

Technical FAQ

How does the module handle output short circuits?The F60 DIO 24/16 01 includes built-in protection mechanisms that monitor current levels and will shut down the affected channel to prevent hardware damage, resuming operation once the fault is cleared.

Is this module compatible with all HIMatrix F60 chassis?Yes, it is designed for standard F60 racks and communicates via the system backplane to ensure high-speed safety data exchange.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more