PRODUCT SKU : UR6AV

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview  

The GE UR6AV module is a digital input expansion unit designed for the Multilin Universal Relay (UR) series. It provides eight dedicated input channels, enabling reliable signal acquisition and monitoring for power system protection and automation applications.

Technical Specifications

  • Manufacturer: General Electric Multilin

  • Model: UR6AV

  • Type: Digital Input Module

  • Input Channels: 8 digital inputs

  • Input Type: Dry contact digital input

  • Nominal Voltage: 24 V DC (standard operating voltage)

  • Compatibility: Fully integrates with GE Multilin UR series relays

  • Weight: Approx. 0.8 kg

  • Dimensions: 170 mm × 105 mm × 32 mm

  • Operating Temperature: -20°C to +70°C (-4°F to +158°F)

  • Storage Temperature: -40°C to +70°C (-40°F to +158°F)

  • Humidity Range: 5% to 95% RH (non-condensing)

Key Features

  • Eight independent digital input channels for flexible monitoring

  • Seamless integration with UR series relays for expanded functionality

  • High reliability in industrial and utility environments

  • Compact design for efficient installation and maintenance

Applications

  • Power system event monitoring

  • Relay input expansion for automation systems

  • Signal acquisition in substations and industrial facilities

  • Integration into UR relay-based protection schemes

FAQ

  • Q: How many input channels does the UR6AV provide?  A: The module offers 8 digital input channels.

  • Q: What type of inputs are supported?  A: Dry contact digital inputs with nominal 24 V DC operation.

  • Q: Is the UR6AV compatible with all UR series relays?  A: Yes, it is designed specifically for the Multilin UR series.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more