Skip to content

What are you looking for?


You may also like

GE IS200AEPAH1ACB Mark VI Analog Input BoardGE IS200AEPAH1ACB Mark VI Analog Input BoardGE IS200AEPAH1ACB Mark VI Analog Input Board
GE IS200AEPAH1ACB Mark VI Analog Input Board
GE IS200AEPAH1ACB Mark VI Analog Input Board
GE IS200AEPAH1ACB Mark VI Analog Input Board

GE IS200AEPAH1ACB Mark VI Analog Input Board


Only 10 left - Selling fast

PRODUCT SKU : IS200AEPAH1ACB

PRODUCT TYPE : Analog Input Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IS200AEPAH1ACB, also cataloged as the IS200AEPA Analog Input Card, operates as a dedicated hardware component for analog input signal processing and system integration within GE Fanuc automation and control systems.

Hardware Specifications

Parameter Specification
Model IS200AEPAH1ACB
Brand GE / General Electric
Origin USA
Weight 0.76 kg
Dimensions 812 mm x 516 mm x 825 mm
Operating Temp Industrial Cabinet Operating Limits
Power Consumption Rack Backplane Powered
Product Type Analog Input Card
Onboard Processor High-Performance Processing Architecture
Communication Protocols Ethernet, Modbus TCP/IP

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The IS200AEPAH1ACB processes incoming field analog signals and transfers digitized data blocks over high-speed system buses without introducing loop latencies. High-speed signal sampling maintains backplane bus communication velocity across adjacent controller slots. Integrated non-volatile memory chips retain onboard board identity and flash configurations, ensuring firmware flash compatibility and immediate parameter synchronization during rack startup sequences.

Frequently Asked Questions

Q: How does the IS200AEPAH1ACB communicate processed analog data to higher-level controllers?

A: The board transmits digitized analog values via integrated backplane channels supporting Ethernet communication and Modbus TCP/IP protocols.

Q: What precautions should be taken regarding hot-swapping the IS200AEPAH1ACB card?

A: The rack frame must be powered down or put into a maintenance state to prevent transient bus errors before inserting or removing the module.

Q: Are manual jumper changes required when updating system firmware?

A: No, internal flash registers automatically verify firmware flash compatibility and load required parameter settings directly from the main processor.

Field Installation Guidelines

  1. Power down the controller rack enclosure and isolate auxiliary signal sources prior to board insertion or removal.
  2. Wear an ESD grounding wrist strap connected to an unpainted metal surface of the control cabinet frame.
  3. Slide the IS200AEPAH1ACB card smoothly into the designated card guide slot until the edge connectors engage the backplane socket.
  4. Tighten top and bottom faceplate captive screws to secure the physical assembly into place.
  5. Ensure all field signal cable shields are grounded at a single point to prevent ground loop interference on analog input channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more