Skip to content

What are you looking for?


You may also like

GE Fanuc DS200EXPSG3 Exciter Power Supply ModuleGE Fanuc DS200EXPSG3 Exciter Power Supply ModuleGE Fanuc DS200EXPSG3 Exciter Power Supply Module
GE Fanuc DS200EXPSG3 Exciter Power Supply Module
GE Fanuc DS200EXPSG3 Exciter Power Supply Module
GE Fanuc DS200EXPSG3 Exciter Power Supply Module

GE Fanuc DS200EXPSG3 Exciter Power Supply Module


Only 10 left - Selling fast

PRODUCT SKU : DS2020EXPSG3

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE DS200EXPSG3, also cataloged as the DS2020EXPSG3 Power Supply Module, operates as a dedicated hardware component for power regulation within the EX2000 brushless generator excitation subsystem of the Mark V turbine control platform.

Hardware Specifications

Parameter Specification
Model DS2020EXPSG3
Brand GE (General Electric)
Origin USA
Dimensions Multi-tier modular assembly
Operating Temp Standard industrial ambient range
Assembly Components Integrated DS200GDPA and DS200EXPS PCBs
Protection Insulated mounting standoffs; plexiglass shield

PLC/DCS Deterministic Network Integration

The DS2020EXPSG3 functions as an integrated power interface, utilizing surface-mounted wiring to facilitate communication between the DS200GDPA (base tier) and DS200EXPS (top tier) circuit boards. The module operates within the EX2000 excitation framework to manage high-voltage regulation via an array of transformers, metal oxide varistors (MOVs), and inductors. The system relies on board-level LED indicators for real-time diagnostic fault monitoring. Integration requires verifying the Mark V controller's firmware flash compatibility to ensure the power supply logic aligns with the specific excitation control algorithms required for the turbine drive assembly.

Frequently Asked Questions

Q: Can the plexiglass safety shield be removed during live operation for diagnostic access?

A: No. The plexiglass shield is a primary safety barrier against electrical shock and burns. Do not remove or bypass this shield while the excitation system is energized.

Q: What is the purpose of the insulated mounting holes on the metal base?

A: The mounting holes are insulated to isolate the metal carrier from the cabinet chassis, preventing potential damaging surface voltages and ground loops that could interfere with the board's high-voltage regulation circuitry.

Field Installation Guidelines

  • Static Sensitivity: The DS2020EXPSG3 contains high-sensitivity electronic components. Utilize a grounded anti-static wrist strap throughout the installation process.
  • Mechanical Mounting: Utilize the two top-hat flanges on the base carrier for mounting. Ensure all four factory-drilled installation holes use the provided insulators to maintain chassis isolation.
  • Diagnostic Access: The board is equipped with integrated LED indicators. Ensure the unit is positioned to allow visual access to these LEDs without compromising the plexiglass protective shield.
  • Termination: Secure all connections to the terminal strips. Inspect the surface-mounted wiring between the tiered circuit boards to ensure no displacement occurred during transit or handling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more