Overview

The IC695CMU310 from GE Fanuc is a single-slot central processing unit (CPU) for the RX3i series. It delivers high-speed Boolean execution, flexible communication, and robust memory for advanced control and automation tasks. Designed for universal backplane compatibility, this processor supports multiple protocols and provides reliable performance in industrial environments.

Technical Specifications

  • Model: IC695CMU310

  • Module Type: Central Processing Unit (CMU)

  • Series: RX3i

  • Slots Required: 1 (single slot)

  • Backplane Support: Universal Backplane

  • Communication Ports:

    • 2 isolated ports: RS-232 and RS-485

  • Protocols Supported: Modbus RTU Slave, SNP, Serial I/O

  • Internal Power Requirements:

    • +5 VDC: 1.0 A nominal

    • +3.3 VDC: 1.25 A nominal

  • Memory and Storage:

    • Up to 10 MB battery-backed RAM

    • 10 MB non-volatile flash memory

    • Configurable: %I/%Q 32 Kbits discrete, %AI/%AQ up to 32 Kwords, symbolic memory up to 10 MB

  • Battery Options:

    • RX3i Lithium Smart Battery (IC695ACC302 recommended)

    • Series 90-30 Lithium Battery Pack (IC693ACC302)

    • Smart Coin Cell (IC698ACC701)

  • Performance:

    • Boolean execution speed: 0.195 ms per 1000 instructions (typical)

    • Floating-point arithmetic supported

  • Clock Accuracy:

    • Time of Day: Max drift 2 s/day

    • Elapsed Time: 0.0% maximum error

  • Program Capacity: Up to 512 program blocks, max 128 KB per block

  • Embedded Communication: RS-232, RS-485

  • Backplane Compatibility: Dual bus support (RX3i PCI and 90-30 style)

  • PCI Compliance: Electrically compatible with PCI 2.2 standard

  • Operating Temperature: 0°C to 60°C (optional -40°C to +60°C)

Applications

  • Central processor for RX3i PACSystems in factory automation

  • Supports real-time control of distributed I/O and networked devices

  • Suitable for process, machine, and infrastructure control requiring high reliability

FAQ

  • Q: Does IC695CMU310 support floating-point operations?
    A: Yes, floating-point arithmetic is supported for advanced calculations.

  • Q: What communications protocols are compatible?
    A: Supports Modbus RTU Slave, SNP, Serial I/O, RS-232, RS-485.

  • Q: How much user program memory is available?
    A: Up to 10 MB battery-backed RAM and 10 MB non-volatile flash memory.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more