PRODUCT SKU : IC694MDL655

PRODUCT TYPE : DC Input Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694MDL655 input module from GE Fanuc PACSystems RX3i series is a high-density discrete input unit designed for flexible DC signal monitoring. Supporting both positive and negative logic, it provides 32 input points organized into four groups, ensuring efficient wiring and reliable detection. With fast response times, robust isolation, and compact design, this module is ideal for demanding automation environments.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Product Line: PACSystems RX3i

  • Part Number: IC694MDL655

  • Product Type: Discrete Input Module

  • Number of Channels: 32 inputs

  • Groups: 4 groups of 8 channels each

  • Logic Type: Positive and Negative logic supported

  • Nominal Input Voltage: 24 VDC

  • Rated Voltage: 48 VDC

  • Input Voltage Range: 0–30 VDC

  • Input Current: 7 mA at rated voltage

  • On-State Voltage: 11.5–30 VDC

  • Off-State Voltage: 0–5 VDC

  • On-State Current: 3.2 mA

  • Off-State Current: ≤ 1.1 mA

  • Response Time: 2 ms maximum (on and off)

  • Current Draw: 195 mA max from +5 V bus; 224 mA typical from isolated +24 V bus with all inputs ON

  • Cable Length: Up to 30 m

  • Isolation: 250 VAC continuous

  • Connector Type: Two male 24-pin connectors

  • Operating Temperature: 0–60 °C (32–140 °F)

  • Storage Temperature: -40–85 °C (-40–185 °F)

  • Humidity Range: 5–95% non-condensing

  • Weight: 0.56 lbs (0.26 kg)

  • Lifecycle Status: Active

Application Scenarios

  • High-density input monitoring in PLC-based machine control systems

  • Automation environments requiring dual logic flexibility

  • Industrial setups needing fast response and reliable isolation

FAQ

Q: How many input channels are available?  A: 32 input points divided into four groups of eight.

Q: What logic types are supported?  A: Both positive and negative logic configurations.

Q: What is the typical response time?  A: 2 milliseconds for both on and off states.

Q: What connectors are used?  A: Two male 24-pin connectors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more