Configured for network interfacing within Mark V drive and turbine control platforms, the GE DS200SLCCG1ACC (DS200SLCCG1 LAN Communication Card) provides direct physical data exchange and local control processing.

Hardware Specifications

Parameter Specification
Model DS200SLCCG1ACC
Brand General Electric
Core Function LAN communication and processor interfacing

Industrial Control & Firmware Compatibility

The DS200SLCCG1ACC integrates a LAN Control Processor (LCP) and utilizes dual-ported RAM to facilitate deterministic data exchange with the host drive control board. For consistent system operation, the backplane bus communication velocity must remain synchronized with the LCP processing cycle to prevent data bottlenecks. Firmware-related parameters are managed via the two onboard EPROM memory modules; these components must maintain version parity with the host controller firmware to ensure correct I/O density scaling and operational stability. The module supports both isolated and non-isolated communication channels, requiring strict adherence to hardware configuration standards to prevent electrical noise coupling from the network medium into the control bus.

Frequently Asked Questions

Q: How is the module interfaced with the host drive controller?

A: The board utilizes dual-ported RAM to create a shared memory buffer between the LCP and the drive control board. This allows for simultaneous, independent access by both microprocessors for high-speed data transfer without external polling.

Q: What is the utility of the attachable alphanumeric keypad?

A: The 16-position alphanumeric display provides a physical interface for users to access system control settings and perform local diagnostics directly on the communication module, facilitating rapid status assessment.

Field Installation Guidelines

  • Physical Seating: Ensure the card is inserted into the designated drive cabinet slot. Verify that all backplane connectors are fully engaged to prevent intermittent communication failures, which can trigger system-wide control faults.
  • Shielding and Grounding: The module incorporates both isolated and non-isolated circuitry. Ensure that external network cabling is properly shielded and that the cabinet ground is securely bonded. Failure to isolate the signal path correctly can result in ground loops affecting data integrity.
  • Memory Handling: When replacing or servicing the EPROM memory modules, utilize ESD-safe handling procedures. Ensure proper orientation during installation to prevent damage to the U1 LCP and its peripheral support logic.
  • Diagnostic Verification: Following installation, attach the 16-position keypad to the designated port to verify initialization. Monitor for error codes or status messages that indicate successful handshaking between the card and the host drive controller.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more