Skip to content

What are you looking for?


You may also like

General Electric DS200DDTBG2A LCI Auxiliary I/O Terminal BoardGeneral Electric DS200DDTBG2A LCI Auxiliary I/O Terminal BoardGeneral Electric DS200DDTBG2A LCI Auxiliary I/O Terminal Board
General Electric DS200DDTBG2A LCI Auxiliary I/O Terminal Board
General Electric DS200DDTBG2A LCI Auxiliary I/O Terminal Board
General Electric DS200DDTBG2A LCI Auxiliary I/O Terminal Board

General Electric DS200DDTBG2A LCI Auxiliary I/O Terminal Board


Only 10 left - Selling fast

PRODUCT SKU : DS200DDTBG2A

PRODUCT TYPE : I/O Terminal Boards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The General Electric DS200DDTBG2A, also cataloged as the DS200DDTB LCI Auxiliary I/O Terminal Board, operates as a dedicated hardware component for high-voltage signal conditioning and interface distribution within Mark V LM Speedtronic turbine control platforms.

Hardware Specifications

Parameter Specification
Model DS200DDTBG2A
Brand General Electric
Origin USA
Dimensions Panel/rack-mounted form factor
Operating Temp -20 deg C to +60 deg C
Power Consumption Derived from ADMA module
Voltage Range 14 V dc to 32 V dc
I/O Channels 12 total

Industrial Control and Firmware Compatibility

The DS200DDTBG2A requires backplane bus communication velocity settings compatible with the Mark V LM rack architecture. Firmware flash compatibility is managed through the interconnected DS200ADMA daughterboard, which interfaces with the DSPC processor. The board supports I/O density scaling by allowing multiple high-voltage and current-sensing signals to be multiplexed into the DSP control loops. Deterministic network performance is maintained as the DDTB provides the necessary scaling and buffering for the DSP to execute real-time control algorithms. Ensure all terminal board jumpers and configuration settings are verified against the specific turbine control system logic.

Frequently Asked Questions

Q: Can the 4-20 mA current output and voltage output be used simultaneously?

A: Yes. The board supports both output types actively. They can be used individually or simultaneously by connecting to the respective screw terminals provided for each output type.

Q: What is the isolation rating for the high-voltage AC inputs?

A: The high-voltage AC inputs use isolated step-down transformers and passive filtering. The screw terminal blocks and internal circuit paths are rated and isolated for 1000 V peak transients.

Q: How is the board powered in the LCI system?

A: Power is supplied to the DS200DDTBG2A via the DS200ADMA analog-to-digital module daughterboard through high-density connectors and a ribbon cable interface.

Field Installation Guidelines

  • Mounting: Secure the board to the rack or panel using appropriate hardware. Ensure sufficient clearance is maintained for the high-density ribbon cable routing.
  • Signal Wiring: Use shielded twisted-pair cables for all analog and current-sensing inputs. Ensure cable shields are terminated at the cabinet entry to prevent electromagnetic interference (EMI).
  • High-Voltage Handling: Observe all safety protocols when connecting high-voltage AC inputs. Verify that all terminal block screws are tightened to the specified torque to prevent arcing or thermal buildup at the connection points.
  • Current Sensing: For CT inputs (±5 A) and low current signals (±0.224 A), ensure polarity is strictly maintained according to the system wiring diagram to prevent phase errors in the LCI control loop.
  • Grounding: Ensure the board chassis is connected to the protective earth (PE) busbar to provide a stable reference for the differential buffering stages.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more