Only 10 left - Selling fast

PRODUCT SKU : VMIVME-7750-734

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for digital-to-analog signal conversion in VMEbus systems, the GE VMIVME-7750-734 (VMIVME-7750 Analog Output Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model VMIVME-7750-734
Brand GE Fanuc
Origin United States
Weight Standard VME Slot Weight
Dimensions Single-slot VMEbus Form Factor
Operating Temp 0 - 60 deg C
Power Consumption System-fed via VMEbus Backplane
Channel Count 32 channels
Resolution 12 bits
Interface Type VMEbus
Signal Output Type Analog Voltage/Current
Linearity High Linearity Profile

Backplane Channel Segregation and I/O Density Scaling

The VMEbus architecture utilizes dedicated addressing lines to execute high-speed parallel data transfers across the backplane. The module accommodates high I/O density scaling by mapping 32 independent channels within a single-slot VME form factor. This high density requires precise register allocation and internal crosstalk suppression circuits to prevent signal degradation during concurrent high-velocity channel updates.

Frequently Asked Questions

Q: Does the module support hot-swapping within an active VMEbus chassis?

A: No. The VMEbus standard utilized by this module lacks live-insertion pin sequencing. Removing or inserting the hardware while the backplane is energized will cause electrical transients, disrupting bus communications and causing system faults.

Q: How is channel ground loops avoided across the 32 output terminals?

A: The 32 output channels share a common ground reference linked to the VMEbus power return line. External field wiring must maintain isolated loops or use external signal conditioners to prevent common-mode ground loop currents from degrading the 12 bits resolution accuracy.

Field Installation Guidelines

  • Chassis Positioning: Turn off all chassis power before sliding the module into the VME backplane slot guides. Verify that the top and bottom mechanical injector/ejector handles lock fully to guarantee pin mating engagement.
  • Grounding Compliance: Ground the VME chassis enclosure frame directly to a low-impedance master ground bus to minimize static interference and protect the 12 bits digital-to-analog converters from high-frequency noise.
  • Signal Shielding: Connect all 32 analog signal output lines using shielded twisted-pair cables. Terminate the shield at the cabinet entry gland plate and avoid routing parallel to high-voltage AC conductors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more