Skip to content

What are you looking for?


You may also like

GE IS230TDBTH6A Discrete I/O BoardGE IS230TDBTH6A Discrete I/O BoardGE IS230TDBTH6A Discrete I/O Board
GE IS230TDBTH6A Discrete I/O Board
GE IS230TDBTH6A Discrete I/O Board
GE IS230TDBTH6A Discrete I/O Board

GE IS230TDBTH6A Discrete I/O Board


Only 10 left - Selling fast

PRODUCT SKU : IS230TDBTH6A

PRODUCT TYPE : Discrete I/O Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IS230TDBTH6A, also cataloged as the IS230TDBTH6A Discrete I/O Board, operates as a dedicated hardware component for TMR contact input and relay output execution within Mark VIe control platforms. Configured for high-density signal handling, this terminal board provides direct physical execution of twenty-four isolated contact inputs and twelve form-C relay outputs.

Hardware Specifications

Parameter Specification
Model IS230TDBTH6A
Brand GE
Origin USA
Weight Not specified
Dimensions 17.8 cm wide x 33.02 cm high
Operating Temp -30 deg C to 65 deg C
Power Consumption System-dependent
Core Performance 24 contact inputs; 12 form-C relay outputs

Industrial Control and I/O Density Scaling

The IS230TDBTH6A facilitates I/O density scaling through a triple modular redundancy (TMR) architecture requiring three PDIO I/O packs. Each contact input features integrated hardware filtering (4 ms) and noise suppression circuitry to mitigate surge and high-frequency interference. The board supports field-selectable wetting voltages of 24 VDC, 48 VDC, or 125 VDC. Communication with the R, S, and T controllers is established via three dedicated D-type connectors (JR1, JS1, JT1), enabling redundant Ethernet networking to each associated PDIO pack. Firmware flash compatibility and deterministic data exchange are managed by the PDIO packs, which require all three modules to be present for correct TMR operation; single I/O pack deployment is not supported by the TDBT hardware configuration.

Frequently Asked Questions

Q: Can the IS230TDBTH6A be operated with a single PDIO I/O pack?

A: No. The TDBT board is engineered specifically for TMR redundancy. Attempting to run the system with a single I/O pack will result in incomplete logic voting and system-level communication faults.

Q: How are the contact inputs protected against electrical noise?

A: The contact inputs are equipped with onboard hardware filters and noise suppression components designed to reject high-frequency interference and voltage surges from field wiring.

Field Installation Guidelines

  • Mounting: The board supports both DIN-rail mounting and flat-surface installation. Ensure the mounting orientation allows for adequate clearance of the three PDIO I/O pack connections.
  • Wiring: Connect external contact inputs to the board while ensuring the wetting voltage matches the specified nominal input range (24/48/125 VDC). Use shielded cabling for input circuits to maintain noise immunity.
  • Grounding: Establish a robust ground connection between the board chassis and the cabinet ground bus to ensure the efficacy of the surge protection circuitry.
  • Connectivity: Verify the correct mapping of D-type connectors to the corresponding controller networks (JR1 to R, JS1 to S, JT1 to T) to maintain the integrity of the TMR voting architecture.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more