Skip to content

What are you looking for?


You may also like

GE IS215WEPAH2BA Mark VIe Wind Energy Pitch Axis Control ModuleGE IS215WEPAH2BA Mark VIe Wind Energy Pitch Axis Control ModuleGE IS215WEPAH2BA Mark VIe Wind Energy Pitch Axis Control Module
GE IS215WEPAH2BA Mark VIe Wind Energy Pitch Axis Control Module
GE IS215WEPAH2BA Mark VIe Wind Energy Pitch Axis Control Module
GE IS215WEPAH2BA Mark VIe Wind Energy Pitch Axis Control Module

GE IS215WEPAH2BA Mark VIe Wind Energy Pitch Axis Control Module


Only 10 left - Selling fast

PRODUCT SKU : IS215WEPAH2BA

PRODUCT TYPE : Pitch Control Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for pitch axis position loop execution in Mark VIe Wind turbine platforms, the GE IS210WEPAH2BA (IS215WEPA Wind Energy Pitch Axis Control Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model IS215WEPAH2BA
Brand General Electric
Origin USA
Weight 0.75 kg
Dimensions 175 x 120 x 35 mm
Operating Temp -30 to 65 deg C
Power Consumption 10 W
System Series Mark VIe Wind
Functional Acronym WEPA
Turbine Rating Up to 30 MN class turbines
CAN Bus Interface Non CAN bus-compatible
Voltage Suppression Integrated transient surge suppression circuitry
PCB Protection Conformal Coating

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The IS215WEPAH2BA module executes localized pitch control algorithms while interfacing directly with host Mark VIe controller racks via high-speed internal bus links. Internal logic circuits optimize data throughput to preserve backplane bus communication velocity during real-time position control cycles. Native firmware flash compatibility enables seamless parameter synchronizing during system initialization without requiring physical flash memory chip replacements or manual hardware jumpers.

Frequently Asked Questions

Q: Is the IS215WEPAH2BA module compatible with CAN bus network interfaces?

A: No, the IS215WEPAH2BA module design is explicitly non CAN bus-compatible and utilizes internal Mark VIe point-to-point rack interfaces.

Q: What protective measures are applied to the PCB for outdoor or harsh turbine environments?

A: The printed circuit board features factory conformal coating to protect onboard components from moisture, airborne contamination, and thermal cycling.

Q: How does the module handle transient voltage spikes on field control lines?

A: The module incorporates built-in transient voltage suppression circuitry designed to clamp incoming electrical surges before they reach sensitive processing logic.

Field Installation Guidelines

De-energize all incoming power feeds to the pitch cabinet and rack prior to handling the module. Fasten a grounded ESD wrist strap to the enclosure frame to prevent electrostatic discharge from damaging sensitive integrated circuits. Align the module with the slot guides in the card cage, slide it straight in until the backplane connectors seat firmly, and torque the front panel retaining fasteners hand-tight. Ensure all field cable drain wires are grounded at the designated chassis grounding rail to maintain noise immunity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more