GE DS200TCEAG1BRE Emergency Over Speed BoardGE DS200TCEAG1BRE Emergency Over Speed BoardGE DS200TCEAG1BRE Emergency Over Speed Board
GE DS200TCEAG1BRE Emergency Over Speed Board
GE DS200TCEAG1BRE Emergency Over Speed Board
GE DS200TCEAG1BRE Emergency Over Speed Board

GE DS200TCEAG1BRE Emergency Over Speed Board


Only 10 left - Selling fast

PRODUCT SKU : DS200TCEAG1BRE

PRODUCT TYPE : Protection Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for turbine protection and trip execution within Mark V Speedtronic control systems, the GE DS200TCEAG1BRE (DS200TCEAG1 Emergency Over Speed Board) provides direct physical signal monitoring for over-speed and flame detection states.

Hardware Specifications

Parameter Specification
Model DS200TCEAG1BRE
Brand General Electric
Origin Not specified
Core Function Over-speed and flame detection monitoring
Connectivity Pair of bayonet connectors

Industrial Control & Firmware Compatibility

The DS200TCEAG1BRE utilizes an onboard microprocessor and multiple programmable read-only memory (PROM) modules to execute protective trip logic. For seamless system integration, ensure that the board's firmware version is compatible with the existing Mark V control processor revision, as mismatched firmware can lead to initialization errors or incorrect trip setpoints. The board’s I/O density scaling relies on the 30 onboard jumpers, which must be configured to match the specific turbine speed and flame detection parameters of the controlled installation. Backplane bus communication velocity must remain within the design limits of the Mark V architecture to ensure deterministic response times during emergency shutdown events.

Frequently Asked Questions

Q: How is the trip condition signaled to the rest of the drive?

A: The board monitors inputs for over-speed and flame detection conditions. Upon detection of a trip state, the board executes a shutdown sequence by interfacing with the drive components via the integrated bayonet connectors.

Q: Is the jumper configuration user-modifiable?

A: The board contains 30 jumpers that are utilized for hardware-level configuration of speed thresholds and detection logic. These must be set according to the site-specific documentation provided by the manufacturer; unauthorized changes may lead to improper trip behavior or failure to detect turbine over-speed conditions.

Field Installation Guidelines

  • Connector Handling: The board utilizes bayonet-style connectors. When disconnecting, stabilize the board with one hand while applying axial force to the connector with the other. This prevents excessive torque or bending stresses on the female board-mounted connectors.
  • Component Seating: Inspect all 30 jumpers for proper seating before installation. Vibration during turbine operation can cause loosely seated jumpers to lose contact, potentially triggering false trip signals or system diagnostic alarms.
  • ESD Mitigation: As the board contains sensitive PROM modules and a dedicated microprocessor, utilize grounded wrist straps and ESD-safe surfaces during handling to prevent static damage to the internal logic components.
  • Signal Verification: Prior to final commissioning, verify that the flame detection and speed signal inputs are properly shielded at the bayonet connector interface to minimize noise injection, which could interfere with the board's internal detection logic.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more