Skip to content

What are you looking for?


You may also like

GE DS200TCCBG8B Common Extended Analog I/O BoardGE DS200TCCBG8B Common Extended Analog I/O BoardGE DS200TCCBG8B Common Extended Analog I/O Board
GE DS200TCCBG8B Common Extended Analog I/O Board
GE DS200TCCBG8B Common Extended Analog I/O Board
GE DS200TCCBG8B Common Extended Analog I/O Board

GE DS200TCCBG8B Common Extended Analog I/O Board


Only 10 left - Selling fast

PRODUCT SKU : DS200TCCBG8B

PRODUCT TYPE : Analog I/O Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-density signal scaling and conditioning in Mark V LM control systems, the GE DS200TCCBG8B (DS200TCCB Common Extended Analog I/O Board) provides direct physical/electrical execution of data translation between turbine terminal boards and core processing units.

Hardware Specifications

Parameter Specification
Model DS200TCCBG8B
Brand GE (General Electric)
Origin USA
Weight 2 lbs
Operating Temp Standard industrial ambient
Programmable Memory 2 x EEPROMs
Signal Interfacing RTD, 4-20 mA, 0-1 mA, Current/Voltage inputs

Industrial Control Deterministic Network

The DS200TCCBG8B acts as a high-bandwidth signal concentrator within the Mark V control architecture, facilitating data exchange between P1 core TCEB boards and R5 core TBCB terminal boards. To maintain system integrity, the backplane bus communication velocity must be strictly calibrated via the 3PL connector interface. The board's internal processing, governed by dual onboard EEPROMs, ensures deterministic scaling of line current and potential transformer (PT/CT) inputs. Firmware flash compatibility is mandatory; ensure that the revision level of the TCCB aligns with the STCA and TCCA board firmware versions to prevent timing latencies during COREBUS signal propagation.

Frequently Asked Questions

Q: Can the EEPROMs on this board be field-updated if a firmware mismatch occurs?

A: Field updates to the EEPROMs require specialized GE-authorized programming equipment. Do not attempt to bypass or force-flash the firmware, as this will lead to non-deterministic signal scaling and potential turbine trip conditions due to feedback data corruption.

Q: What are the primary isolation considerations for the JHH, JII, and JMP connectors?

A: These connectors carry high-sensitivity signals (RTD, mA, PT/CT). Shielding must be maintained up to the connector interface to prevent electromagnetic interference. Ensure that the 2PL power distribution from the TCPS board is verified for ripple voltage before connecting signal cables to these ports, as power instability will propagate through the analog conditioning circuits.

Field Installation Guidelines

  • Connector Alignment: Carefully align the 3PL, 2PL, JHH, JII, and JMP connectors during installation. Avoid applying lateral force, which can cause micro-cracking in the PCB solder joints or bent connector pins.
  • Signal Integrity: Maintain physical segregation between the 3PL data bus cabling and high-voltage power lines. Induced noise on the 3PL bus can result in intermittent communication failures between the STCA, TCCA, and TCCB boards.
  • Static Sensitivity: The DS200TCCBG8B assembly is sensitive to electrostatic discharge. Ensure the technician is connected to a common earth-ground point when handling or inspecting the module.
  • Component Verification: Prior to system energization, verify that the board is firmly seated in its rack guides. Inspect the connection at the 3PL port to ensure a low-impedance path for the COREBUS signals.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more