GE DS200LRPBG1AAA Resolver BoardGE DS200LRPBG1AAA Resolver BoardGE DS200LRPBG1AAA Resolver Board
GE DS200LRPBG1AAA Resolver Board
GE DS200LRPBG1AAA Resolver Board
GE DS200LRPBG1AAA Resolver Board

GE DS200LRPBG1AAA Resolver Board


Only 10 left - Selling fast

PRODUCT SKU : DS200LRPBG1AAA

PRODUCT TYPE : Resolver Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-precision rotor feedback processing in Mark V control systems, the General Electric DS200LRPBG1AAA (DS200LRPBG1AAA Resolver Board) provides direct physical/electrical execution of rotary transformer signal digitization and system interface.

Hardware Specifications

Parameter Specification
Model DS200LRPBG1AAA
Brand General Electric
Origin United States of America (USA)
Input Type Analog resolver (rotary transformer)
Output Type Digitized position/speed data

Industrial Control and Drive Systems

The DS200LRPBG1AAA leverages backplane bus communication velocity to transmit digitized rotor dynamics data to host controllers. The board supports firmware flash compatibility, facilitating refined signal processing algorithms for speed and position feedback loops. Through integrated I/O density scaling, the module converts raw analog inputs into deterministic data formats, essential for synchronizing motor control and turbine management functions. The board architecture includes localized signal refinement circuits and dedicated diagnostic LED indicators that map directly to status registers within the drive control network.

Frequently Asked Questions (FAQ)

Q: How does the board interface with the resolver hardware?

A: The board receives raw analog excitation and feedback signals from the rotary transformer (resolver). Internal microprocessors perform the signal conversion and digitization, preparing the data for transmission to the Mark V control system.

Q: What is the primary purpose of the onboard LED indicators?

A: The diagnostic LEDs provide real-time visual status of the board's operational health, allowing field technicians to identify signal loss, conversion errors, or internal hardware faults without requiring external diagnostic tools.

Field Installation Guidelines

  • Signal Shielding: Resolver signals are sensitive to electromagnetic interference (EMI). Ensure that shielded twisted-pair cables are used for all resolver-to-board connections and that the shield is grounded at a single, clean instrumentation ground point to minimize crosstalk.
  • Connector Integrity: Verify that all cabling connected to the I/O terminals is fully seated. Given the high-frequency nature of resolver signal excitation, any loose connection will result in noise or inaccurate position feedback, potentially causing control instability.
  • Mounting: Ensure the board is securely fastened within the Mark V rack. Vibration can induce mechanical stress on the signal conversion components, leading to drift in the digitized position signal.
  • Grounding: Verify that the rack chassis provides a low-impedance path to the system ground. This is necessary for the stability of the analog-to-digital conversion circuits and to maintain the integrity of the diagnostic status indicators.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more