PRODUCT SKU : DS200DACAG1ACD

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for power regulation and energy storage in Mark V Speedtronic systems, the GE DS200DACAG1ACD (DS200DACA Power Conversion Module) provides direct physical execution of AC to DC voltage conversion.

Hardware Specifications

Parameter Specification
Model DS200DACAG1ACD
Brand General Electric
Origin USA
Operating Temp -30 deg C to 60 deg C
Power Consumption 1000 W (Output rating)
Core Performance 105-132 V AC input, 90-145 V DC output, 9.5 A DC max

Industrial Control & Firmware Compatibility

The DACA module maintains system-wide operational continuity by facilitating local energy storage to extend ride-through time during control power loss. I/O density scaling and parallel operation capabilities are defined by the module revision; while this specific unit functions as a primary converter, newer variants allow for paralleling to increase output current capacity. Firmware flash compatibility is not required, as the conversion logic is handled by internal switching circuitry. System integration requires precise configuration of the internal cable taps (JTX1 for 115 V AC or JTX2 for 230 V AC) to match the facility supply, ensuring deterministic voltage regulation for the 125 V DC control bus.

Frequently Asked Questions

Q: How is the input voltage range selected for this module?

A: Input voltage selection is performed via internal cable configuration. The internal cable must be plugged into connector JTX1 for 115 V AC operations or JTX2 for 230 V AC operations prior to energizing the unit.

Q: Is this module capable of parallel operation to increase output current?

A: Paralleling is generally not recommended for this specific revision. Paralleling capabilities were introduced in later model iterations of the DACA series. Refer to system-level documentation to verify if your specific control architecture supports redundant power supplies.

Field Installation Guidelines

  • Mounting Stability: Secure the module using the four mounting holes provided in the base. Ensure the chassis is properly bonded to the cabinet ground to manage transient voltages and heat dissipation.
  • Connector Integration: Utilize the JZ 12-position connector for AC input and DC output. This must be mated securely with the PDM (Power Distribution Module) connector JZ2 or JZ3. Ensure the latching mechanism is fully engaged to prevent vibration-induced disconnection.
  • Polarity Verification: Confirm the DC output polarity matches the system control bus requirements before finalizing connections. Reverse polarity can cause immediate damage to connected control electronics.
  • Thermal Environment: The module operates across a wide temperature range (-30 to 60 deg C). Ensure adequate ventilation is maintained around the module to prevent premature failure of internal electrolytic capacitors, which are critical for the local energy storage/ride-through function.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more