Configured for contactor control and excitation management in EX2000 systems, the GE DS200CPCAG1A (DS200CPCA Contactor Pilot Board) provides direct physical/electrical execution of coil switching sequences.

Hardware Specifications

Parameter Specification
Model DS200CPCAG1A
Brand GE (General Electric)
Origin USA
Weight 0.45 kg
Dimensions 23.8 cm x 8.6 cm
Operating Temp -35 to 65 deg C
Power Consumption 25 VDC (Control Logic)
Input Voltage 115 VAC
Output Voltage 105 VDC (Contactor Coil Drive)

PLC/DCS Deterministic Network Integration

The DS200CPCAG1A manages contactor state transitions by rectifying 115 VAC input into 105 VDC output for coil actuation. Integration into the EX2000 system requires precise coordination with the existing backplane bus communication velocity. As a critical link in the excitation sequence, this board maintains deterministic timing during state changes, ensuring that coil voltage is sustained to keep the contactor closed. Firmware flash compatibility and hardware handshaking protocols must be verified against the host controller revision to prevent timing latencies during high-frequency switching operations.

Frequently Asked Questions

Q: Can the test points CPH and CPN be measured with standard grounded multimeters?

A: No. CPH and CPN are not referenced to the drive's common level. All measurements must be performed using isolated test equipment capable of measuring floating potentials to prevent circuit damage or ground fault conditions.

Q: How does the CPCA functionality differ from the CDBA board in terms of load handling?

A: While the CDBA board initiates the electricity for contactor operation, the CPCA board provides the full voltage required to close and maintain the contactor in a closed state, assuming the primary load responsibilities for the coil drive.

Field Installation Guidelines

  • Mounting: Ensure the board is securely seated in the designated EX2000 cabinet slot using the provided guide rails. Verify mechanical clearance for the 23.8 cm x 8.6 cm footprint.
  • Wiring: Use appropriate gauge wire for the 115 VAC input connections. Ensure all terminals are tightened to specified torque values to prevent high-resistance connections and overheating during continuous coil activation.
  • Grounding and Shielding: Ensure the cabinet chassis is properly earth-grounded. Because the board handles AC-to-DC conversion for inductive loads, maintain physical separation between signal cables and high-power conductors to mitigate electromagnetic interference.
  • Testing: Before applying full system power, perform continuity checks using isolated equipment at the designated test points (CPH, CPN, PSP, PSN) to verify correct voltage polarity and conversion levels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more