Product Details

Configured for backplane power distribution and internal communication routing in Foxboro I/A Series system enclosures, the Foxboro P0926HTA (P0926HT Modular Baseplate) provides direct physical/electrical execution for mounting DIN rail 200 Series modules. It accommodates up to 8 modules to route power and digital data signals across the backplane bus.

Hardware Specifications

Parameter Specification
Model P0926HTA
Brand Foxboro
Origin USA
Weight Standard 8-slot baseplate weight
Dimensions Standard 8-slot DIN rail enclosure dimensions
Operating Temp -20 deg C to +60 deg C
Power Consumption Passive backplane assembly (0 W base consumption)
Slot Capacity 8 module positions
Input Signal Ranges -20 to 60 VDC, 4 to 20 mA, 0 to 10 VDC, 0 to 200 mV
Measurement Accuracy +/-0.1% of full scale
Compatible Hardware FCP280, FDC280, FCP270, FCM100Et, FCM100E, FEM100E, FBI200, FBI100, FBMs

Channel-to-Channel Isolation and Loop Protocol Connectivity

The Foxboro P0926HTA baseplate incorporates channel-to-channel isolation architecture across its backplane traces to reduce noise interference and prevent ground loops between field modules. It maintains signal fidelity for 4-20 mA HART loop protocol field instruments and protects low-level voltage inputs down to 0 to 200 mV from high-frequency electrical transients, preventing thermal drift at cold junction compensation (CJC) terminals on connected I/O units.

Frequently Asked Questions

Q: What control processors and interface modules can be installed on the P0926HTA baseplate?

A: The P0926HTA supports Field Control Processors FCP280 and FCP270, Field Device Controller FDC280 (in fault-tolerant or non-fault-tolerant options), FCM100Et/FCM100E communications modules, FEM100E expansion modules, FBI200/FBI100 isolators, and standard FBMs.

Q: How does the P0926HTA handle low-level analog input signals?

A: The backplane provides shielding against electrical noise, maintaining signal processing accuracy within +/-0.1% of full scale for millivolt and milliamp signal ranges.

Field Installation Guidelines

Mount the P0926HTA modular baseplate securely onto standard DIN rails inside the enclosure, verifying that all mounting clips snap fully into place. Ensure primary DC power feeds to the baseplate mounting position are isolated before inserting or removing modules on the backplane connector slots.

Route field wiring cables through designated cable channels, maintaining separation between high-voltage power lines and low-level analog signal paths. Verify that cabinet chassis ground connections are bonded to the main earth ground bar, and ensure all panel conduit entries maintain a minimum of 5 full threads of engagement on NPT fittings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more