Skip to content

What are you looking for?


You may also like

P0916AA FBM201 | Foxboro | I/A Series 8-Channel Analog Input ModuleP0916AA FBM201 | Foxboro | I/A Series 8-Channel Analog Input ModuleP0916AA FBM201 | Foxboro | I/A Series 8-Channel Analog Input Module
P0916AA FBM201 | Foxboro | I/A Series 8-Channel Analog Input Module
P0916AA FBM201 | Foxboro | I/A Series 8-Channel Analog Input Module
P0916AA FBM201 | Foxboro | I/A Series 8-Channel Analog Input Module

P0916AA FBM201 | Foxboro | I/A Series 8-Channel Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : FBM201 P0916AA

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Foxboro FBM201 (P0916AA) functions as a high-integrity analog input interface for the Foxboro I/A Series Distributed Control System (DCS). This module accepts eight independent analog signals from field transmitters, converting them into digital values for the system's redundant Fieldbus. It serves as a foundational component for process monitoring in refineries, chemical plants, and power utilities. We supply this unit as 100% Brand New and Original, ensuring your control loops benefit from factory-fresh circuitry and zero previous field runtime.

Technical Specifications

Feature Specification Details
Manufacturer Foxboro (Schneider Electric)
Model Number FBM201
Part Number P0916AA
Number of Terminals 8
Terminal Type Screw Terminals
Wiring Connection Ring Lug
Ingress Protection IP66
Operating Temperature -40 to 80°C (-40 to 176°F)
Relative Humidity 0 to 95% RH (Non-condensing)

Engineering Advantages

The FBM201 P0926AA overcomes rigorous environmental and electrical challenges through specialized hardware engineering:

  • Extreme Thermal Resilience: The module operates consistently within a wide range from -40 to 80°C. This industrial hardening permits installation in remote marshalling cabinets exposed to desert heat or Arctic cold without requiring specialized HVAC climate control.

  • Superior Ingress Protection: The IP66-rated construction shields the internal electronics against high-pressure water jets and heavy dust. This ensures the module maintains signal integrity in wash-down areas or facilities with high particulate concentrations.

  • High-Security Wiring Interface: The screw-type terminals accommodate ring lug wiring. This connection method prevents accidental wire pull-outs and ensures a gas-tight electrical contact, which is critical for maintaining low-impedance analog signals in high-vibration environments.

  • Minimized Signal Drift: The 200 Series architecture utilizes high-stability semiconductors that minimize thermal drift. This ensures the 4-20 mA or 0-20 mA inputs remain accurate across the entire operating temperature spectrum, reducing the frequency of system-level recalibration.

  • Ruggedized Fieldbus Integration: The module integrates directly with the redundant 2 Mbps Fieldbus. It withstands electromagnetic interference (EMI) typical of heavy industrial zones, preventing data corruption between the field devices and the Field Control Processor (FCP).

FAQs

  • What type of wiring is best for the FBM201 P0916AA? The module utilizes screw terminals specifically designed for ring lug connections. This choice maximizes contact surface area and provides the highest level of vibration resistance for your analog signal loops.

  • Does this module support hot-swapping? Yes. The I/A Series 200 Series design allows you to remove and replace the FBM201 without powering down the modular baseplate. The system automatically re-establishes communication with the Brand New module upon seating.

  • Can I use the FBM201 in outdoor enclosures? With its IP66 rating and -40 to 80°C operating range, the FBM201 excels in outdoor or non-climate-controlled environments, provided the enclosure itself prevents direct exposure to standing water and UV radiation.

  • Is the P0916AA a direct replacement for existing FBM201 units? Absolutely. As a 100% Brand New original part, it serves as a drop-in replacement for any failed or aging FBM201 module on a 200 Series baseplate, maintaining full software and electrical compatibility.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more