The Foxboro P0926KH, also cataloged as the P0926KH Modular Baseplate, operates as a dedicated hardware component for module mounting and backplane bus routing within Foxboro Evo Process Automation System architecture. It provides power connections and signal backplane execution across 2 Mbps standard fieldbus channels and 268 Kbps lines dedicated to 100 Series Fieldbus Modules (FBMs).

Hardware Specifications

Parameter Specification
Model P0926KH
Brand Foxboro
Origin USA
Weight 0.85 lbs (0.39 kg)
Dimensions 150 mm x 100 mm x 30 mm
Operating Temp -40 deg C to +70 deg C
Power Consumption Primary and secondary 24 VDC connections
Mounting Options Vertical and horizontal DIN-rail mounting
Fieldbus Compatibility 2 Mbps Fieldbus (standard) / 268 Kbps Fieldbus (100 Series FBMs)
Operating Humidity 5% to 95% non-condensing
Shock / Vibration 10 g peak (11 ms) / 0.7 g from 13.2 Hz to 150 Hz

Process Loop Signal Conditioning and Channel Isolation

The Foxboro P0926KH incorporates dedicated backplane isolation channels designed to decouple high-frequency digital communications from field-side wiring loops. By isolating the internal dual 24 VDC distribution paths from field I/O connections, the baseplate prevents common-mode noise and ground loop currents from interfering with 4-20 mA HART loop protocol signaling across connected control modules.

Frequently Asked Questions

Q: Does the P0926KH support simultaneous operation of 200 Series modules and legacy 100 Series FBMs?

A: Yes, the backplane integrates dual communication paths running at 2 Mbps for standard modules and 268 Kbps specifically mapped for legacy 100 Series FBM signal processing.

Q: How is power redundancy maintained across the baseplate terminals?

A: The board features discrete primary and secondary 24 VDC bus connections with internal diode isolation, ensuring uninterrupted backplane power if one supply feed fails.

Field Installation Guidelines

Mount the baseplate securely onto standard DIN rails in either vertical or horizontal orientations. Verify that DIN-rail grounding clamps make direct metal-to-metal contact with an unpainted, grounded metallic backpanel to establish an effective protective earth connection.

Connect both primary and secondary 24 VDC feeds using independent, fused power lines. Ensure all fieldbus communication cables maintain proper shielding with drain wires terminated to a single chassis earth point. When passing field cables into panel enclosures, verify that NPT conduit fittings achieve a minimum 5-thread engagement to maintain enclosure mechanical integrity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more