Product Details

The Foxboro AD202MW, also cataloged as the AD202MW Analog Output Module, operates as a dedicated hardware component for converting digital controller commands into calibrated analog current signals within Foxboro DCS architectures. The module delivers 4-20 mA output currents across up to 32 channels with 16-bit resolution and a 1 millisecond response time to drive process actuators and control valves.

Hardware Specifications

Parameter Specification
Model AD202MW
Brand Foxboro
Origin USA
Weight 0.45 kg (1.0 lbs)
Dimensions Standard Foxboro module chassis
Operating Temp -40 deg C to +70 deg C
Power Consumption 24 VDC external supply
Channel Count Up to 32 channels
Output Signal 4-20 mA
Signal Accuracy +-0.1% of reading
Resolution 16-bit
Sampling Rate 100 Hz
Response Time 1 millisecond
Loop Resistance 250 ohm
Process Connection 1/2" NPT

Channel-to-Channel Isolation and Loop Protocol Connectivity

The Foxboro AD202MW incorporates internal isolation circuitry between output channels and system backplane logic to isolate control loops from ground potentials. Its 16-bit digital-to-analog architecture stabilizes 4-20 mA HART loop protocol current drivers under varying load conditions up to 250 ohm loop resistance, maintaining signal purity for final control element positioning.

Frequently Asked Questions

Q: What output signal protocol and dynamic range does the AD202MW support?

A: The module generates 4-20 mA analog output signals across up to 32 channels at a 100 Hz sampling rate.

Q: What loop load resistance can be driven by the AD202MW outputs?

A: The module outputs are rated for standard loop loads up to 250 ohm operating from a 24 VDC supply rail.

Field Installation Guidelines

Mount the AD202MW directly into its designated baseplate slot, ensuring top and bottom chassis latches engage securely to maintain backplane contact pressure. De-energize 24 VDC field power sources prior to inserting or removing module connection assemblies.

Route 4-20 mA field output conductors using shielded twisted-pair wire in separate cable trays away from high-voltage motor wires or switching inductive loads. Connect cable drain shields to the central enclosure grounding bar. Where field cabling enters through 1/2" NPT process connections or enclosure glands, verify that threaded joints achieve a minimum of 5 full threads of engagement to maintain physical strain relief.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more