Skip to content

What are you looking for?


You may also like

PR6423/002-031 CON041-CN Emerson Eddy Current Sensor SystemPR6423/002-031 CON041-CN Emerson Eddy Current Sensor SystemPR6423/002-031 CON041-CN Emerson Eddy Current Sensor System
PR6423/002-031 CON041-CN Emerson Eddy Current Sensor System
PR6423/002-031 CON041-CN Emerson Eddy Current Sensor System
PR6423/002-031 CON041-CN Emerson Eddy Current Sensor System

PR6423/002-031 CON041-CN Emerson Eddy Current Sensor System


Only 10 left - Selling fast

PRODUCT SKU : CON041+PR6424/002-031

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for shaft displacement and dynamic vibration measurement in machinery monitoring networks, the Emerson PR6423/002-031 CON041-CN (PR6423 / CON041-CN Proximity Sensors) provides direct physical/electrical execution. The assembly couples an inductive proximity transducer probe with a signal converter module to evaluate spatial variations between the sensor face and target conductive metal surfaces. High-frequency electromagnetic excitation generates eddy currents within the target, converting physical displacement into proportional continuous analog signals for diagnostic input processing.

Hardware Specifications

Parameter Specification
Model PR6423/002-031 CON041-CN
Brand Emerson
Origin United States
Weight 0.32 kg
Dimensions 12.1 cm * 5.2 cm * 16.6 cm
Operating Temp -35 to +180 deg C (Sensor Head)
Power Consumption Standard loop power dissipation
Supply Voltage 24 VDC nominal
Measurement Principle Eddy Current Inductive Proximity
Output Signal 4-20 mA HART loop protocol
Channel Isolation Galvanic signal isolation

4-20 mA HART Loop Protocol & Channel Isolation

The CON041-CN signal processing circuit integrates a 4-20 mA HART loop protocol layer, enabling concurrent analog process variable transmission and digital diagnostic status readout over standard two-wire loops. Internal galvanic channel-to-channel isolation prevents stray ground currents and common-mode potential shifts between adjacent channels in dense monitoring racks. Continuous thermal stabilization circuitry compensates for temperature swings along the sensor lead assembly, preserving measurement slope accuracy across operating limits.

Frequently Asked Questions

Q: How does the CON041-CN converter maintain signal accuracy across multi-channel terminal racks?

A: Galvanic channel-to-channel isolation isolates each measurement channel from adjacent power and signal reference planes, preventing ground loops from distorting continuous 4-20 mA current outputs.

Q: Can the sensor cabling be disconnected or serviced while the loop remains energized?

A: Disconnecting the probe RF connector while power is applied can introduce voltage transients into the conditioning circuit; always isolate the 24 VDC supply prior to servicing sensor connections.

Field Installation Guidelines

Maintain a side-wall clearance equal to at least 1.5 times the probe tip diameter from adjacent housing metals to avoid unintended probe inductance loading. Route field wiring inside dedicated grounded metallic conduits separated from high-voltage motor supply feeds and variable frequency drive wiring. Earth the cable shield at a single technical ground bus inside the cabinet to eliminate ground loops. Ensure probe mounting locking nuts are torqued to standard engineering limits and wrap exposed cable connections with self-amalgamating tape to protect against environmental degradation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more