Skip to content

What are you looking for?


You may also like

MMS 6822 | Emerson EPRO | Modbus RTU/TCP-IP Interface CardMMS 6822 | Emerson EPRO | Modbus RTU/TCP-IP Interface CardMMS 6822 | Emerson EPRO | Modbus RTU/TCP-IP Interface Card
MMS 6822 | Emerson EPRO | Modbus RTU/TCP-IP Interface Card
MMS 6822 | Emerson EPRO | Modbus RTU/TCP-IP Interface Card
MMS 6822 | Emerson EPRO | Modbus RTU/TCP-IP Interface Card

MMS 6822 | Emerson EPRO | Modbus RTU/TCP-IP Interface Card


Only 10 left - Selling fast

PRODUCT SKU : MMS 6822

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for industrial data communication in process control platforms, the Emerson EPRO MMS 6822 (MMS 6822 Interface Card) provides direct electrical execution of Modbus RTU and TCP/IP protocol mapping.

Hardware Specifications

Parameter Specification
Model MMS 6822
Brand Emerson EPRO
Origin Germany
Weight 0.2 kg
Dimensions 90 mm x 60 mm x 25 mm
Operating Temp -20 deg C to 60 deg C
Power Consumption 24 VDC, 100 mA
Resolution 16-bit
Device Capacity Up to 128 Modbus devices

Process Control and DCS Connectivity

The MMS 6822 facilitates seamless integration between field devices and host control systems through robust Modbus RTU and Ethernet-based communication protocols. Featuring channel-to-channel isolation, the card ensures that individual measurement loops remain electrically decoupled, preventing noise propagation in multi-node networks. The module supports diverse input types including ±10 V, ±20 mA, RTD, and thermocouple signals, which are normalized through a 16-bit analog-to-digital converter. For thermal monitoring, cold junction compensation (CJC) is implemented to maintain accuracy in temperature measurement loops, ensuring precise data transmission for all connected Modbus slave devices.

Frequently Asked Questions

Q: Can the MMS 6822 operate simultaneously in RTU and TCP/IP modes?

A: The module supports both protocols to enable flexibility in system integration. However, ensure that the communication bus loading and refresh rates are configured within the limits of the master control system to prevent latency during data polling.

Q: Is this module capable of local I/O expansion?

A: The module acts as an interface card supporting up to 128 devices. It is not designed for direct local I/O expansion but rather serves as a gateway to map field inputs to the Modbus communication structure.

Field Installation Guidelines

  1. Mount the card on a standard DIN-rail, ensuring proper spacing for convective cooling within the enclosure.
  2. Verify the 24 VDC power supply polarity at the input terminals to prevent damage to the internal logic circuitry.
  3. Terminate shielded communication cables at the designated ports, ensuring the cable shield is grounded at a single point to mitigate electromagnetic interference.
  4. Set the Modbus slave address and communication parameters via the system configuration utility before establishing a connection to the network.
  5. Confirm link activity and data integrity by monitoring the status LEDs on the module faceplate during the initial handshake with the Modbus master.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more