Skip to content

What are you looking for?


You may also like

Emerson VE4006P2 M-Series Serial Interface CardEmerson VE4006P2 M-Series Serial Interface CardEmerson VE4006P2 M-Series Serial Interface Card
Emerson VE4006P2 M-Series Serial Interface Card
Emerson VE4006P2 M-Series Serial Interface Card
Emerson VE4006P2 M-Series Serial Interface Card

Emerson VE4006P2 M-Series Serial Interface Card


Only 10 left - Selling fast

PRODUCT SKU : VE4006P2

PRODUCT TYPE : Communication Module

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for serial data acquisition and integration in DeltaV control networks, the Emerson VE4006P2 (VE4006P2 Serial Interface Card) provides direct physical/electrical execution of multi-protocol serial communication across dual independent ports.

Hardware Specifications

Parameter Specification
Model VE4006P2
Brand Emerson
Origin USA
Weight 2.0 kg
Dimensions M-series module form factor
Operating Temp -40 deg C to 70 deg C
Power Consumption System-powered via carrier
Port Configuration 2 independent ports (RS232/422/485)
Baud Rate 300 to 115200 bps

Process Control: Serial Interface Connectivity

The VE4006P2 supports high-density integration with up to 32 data sets (16 per port), enabling seamless interoperability between legacy field devices and the DeltaV control architecture. Each port is physically isolated from the system backplane and from the opposing serial port to prevent common-mode noise propagation. The card supports selectable RS232, RS422/485 half-duplex, and RS422/485 full-duplex transmission modes, providing flexibility for diverse physical layer requirements. The module handles configurable parity (Even, Odd, None) and provides deterministic data polling across a wide spectrum of baud rates, ensuring stable communication performance in high-EMI environments.

Frequently Asked Questions (FAQ)

Q: Are the serial ports on the VE4006P2 internally grounded?

A: No. Each port is isolated from the system and the opposing port, requiring external chassis or signal grounding to maintain the isolation integrity and prevent electrical noise accumulation on the serial lines.

Q: Can the dual ports be used for redundant communications to the same device?

A: Yes. The dual-port architecture allows for redundant serial path configuration. When configured for redundancy, the controller manages the communication switch-over between ports without data loss, provided the external field cabling supports the redundant topology.

Field Installation Guidelines

  • Mounting: The VE4006P2 module must be installed on a DeltaV M-series I/O carrier. Ensure the simplex terminal block is seated securely to maintain the signal ground connection.

  • Wiring: Utilize shielded twisted pair cables for RS422/485 applications. The shield must be terminated at the designated grounding lug on the carrier to minimize protocol conversion latencies and induced interference.

  • Grounding: External grounding of each port is required. Establish a low-impedance path to the cabinet common ground bus to protect the internal isolation barriers from transient voltage surges.

  • Configuration: Verify that baud rate and parity settings in the DeltaV workstation match the connected field device requirements before initiating communication to prevent framing errors or packet corruption.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more