Woodward 5466-318 MicroNet Digital ControllerWoodward 5466-318 MicroNet Digital ControllerWoodward 5466-318 MicroNet Digital Controller
Woodward 5466-318 MicroNet Digital Controller
Woodward 5466-318 MicroNet Digital Controller
Woodward 5466-318 MicroNet Digital Controller

Woodward 5466-318 MicroNet Digital Controller


Only 10 left - Selling fast

PRODUCT SKU : 5466-318

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Woodward 5466-318, also cataloged as the 5466-318 Kernel Power Supply Module, operates as a dedicated hardware component for Triple Modular Redundant (TMR) power regulation within MicroNet TMR control platforms.

Hardware Specifications

Parameter Specification
Model 5466-318
Brand Woodward
Power Consumption 24 VDC
Input Voltage 24 VDC +/- 10%
Output Voltage 5 VDC +/- 5%
Output Current 10 A (max)
CPU Compatibility TMR040
Chassis MicroNet TMR

Triple Modular Redundancy (TMR) 2oo3 Architecture

The 5466-318 is architected specifically for integration into a MicroNet TMR system, functioning as one of three redundant kernel power supply modules. In a TMR 2oo3 architecture, the module ensures continuous operation through fault-tolerant power distribution. The unit performs galvanic isolation between the primary 24 VDC MicroNet bus and the regulated internal 5 VDC rails, ensuring that a failure in a single power module does not propagate to the other two modules within the TMR cluster. Fail-safe state execution is maintained by the synchronization of the three modules, allowing for uninterrupted system power in the event of an individual module fault or input supply disturbance.

Frequently Asked Questions

Q: What is the procedure for removing the 5466-318 module from the MicroNet TMR chassis?

A: Before extraction, all associated kernel power supply modules within the TMR cluster must be removed to prevent electrical contention or backplane damage. Ensure the system is powered down and the modules are extracted in accordance with the specified hardware removal sequence.

Q: How is the power health status indicated on the front faceplate?

A: The front faceplate features a single status LED. When illuminated, this indicator provides visual confirmation of the internal Power Health supply status. If the LED is extinguished, the module is failing to provide the regulated 5 VDC output, signaling a potential internal fault.

Field Installation Guidelines

  1. Mounting: Insert the module into the first slot of the MicroNet TMR kernel section. Ensure the module is seated fully into the backplane connectors to establish electrical continuity.
  2. Environmental Constraints: Installation is limited to non-hazardous locations or Class I, Groups A, B, C, D, Division 2 locations. Verify the installation site environment meets these criteria to prevent operational errors.
  3. Power Cabling: Ensure the 24 VDC main power source is stable and within the +/- 10% tolerance range. Use appropriately rated wiring to support the 10 A current throughput.
  4. Validation: Monitor the front panel LED upon power-up. In a redundant configuration, all three modules must exhibit active status indicators to confirm healthy synchronization of the TMR power bus.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more