Only 10 left - Selling fast

PRODUCT SKU : KL3104X1-BA1

PRODUCT TYPE : Digital I/O Card

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-density discrete output signal processing in DeltaV electronic marshalling subsystems, the Emerson KL3104X1-BA1 (KL3104X1-BA1 Intrinsically Safe Digital Output Module) provides direct physical/electrical execution. This hardware component switches low-energy field infrastructure located within hazardous environments, regulating electrical load actuation circuits while maintaining absolute isolation constraints across the local distributed backplane bus.

Hardware Specifications

Parameter Specification
Model KL3104X1-BA1
Brand Emerson
Origin U.S.A.
Weight 0.08 kg
Dimensions Standard CHARM module footprint slot width
Operating Temp -40 deg C to +70 deg C
Power Consumption +6.3 VDC at 0 mA (CHARM Bus), +24 VDC at 78 mA (Field Circuit)
Output Allocation 45 mA maximum load control loop
Shock Resistance 10g 1/2 sine wave for 11 ms
Vibration Resistance 1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz
Airborne Contaminants ISA-S71.04-1985 Class G3 compliance
Relative Humidity 5% to 95% non-condensing
Terminal Block Key Position 3E

Channel-To-Channel Isolation and Loop Performance

Mechanical execution of this terminal-mounted CHARM module relies on dedicated galvanic separation layers to ensure process loop signal integrity. The hardware architecture incorporates absolute channel-to-channel isolation parameters, checking that ground faults or transient surges on an active discrete field loop cannot propagate to neighboring hardware modules. Internal logic components utilize this electrical boundary to isolate the master controller communication framework from field circuit fluctuations, enabling reliable execution of discrete trip signals and valve actuation steps under continuous power.

Frequently Asked Questions

Q: Does this intrinsically safe output module support hot-swap exchange under live system power?

A: Yes. The hardware is designed for insertion and extraction on an energized terminal baseplate. Internal current-limiting components prevent the generation of backplane bus disturbances or communication drops across adjoining active CHARM tracks during replacement.

Q: What is the mechanical function of the 3E terminal block key assignment?

A: The 3E key position mechanically prevents an incorrect characterization module type from being inserted into a slot wired for this specific output loop configuration, reducing the risk of overvoltage hazards or hardware damage to field assets.

Field Installation Guidelines

  • Baseplate Slot Insertion: Align the rear terminal guides of the CHARM module perpendicularly with the designated baseplate receptor. Press downward until the dual mechanical retention latches click into place to prevent erratic terminal contact.

  • Intrinsically Safe Wiring Separation: All hazardous-area output loop wiring must be routed through segregated blue wiring ducts. Maintain a minimum distance of 50 mm between intrinsically safe control lines and standard non-intrinsically safe power infrastructure.

  • Shield Grounding Strategy: Terminate the cable shields at the carrier grounding bar assembly only. A single-point grounding layout must be verified at the marshalling cabinet to eliminate ground-loop induced currents on the process variable tracking lines.

  • Environmental Enclosure Parameters: For locations with Class G3 airborne contaminant profiles, the marshalling enclosure must maintain a positive-pressure air flow and keep relative humidity below the 95% threshold to eliminate condensation on active terminal contacts.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more