Skip to content

What are you looking for?


You may also like

Honeywell 51403299-100 LCNP4 Process Automation Processor BoardHoneywell 51403299-100 LCNP4 Process Automation Processor BoardHoneywell 51403299-100 LCNP4 Process Automation Processor Board
Honeywell 51403299-100 LCNP4 Process Automation Processor Board
Honeywell 51403299-100 LCNP4 Process Automation Processor Board
Honeywell 51403299-100 LCNP4 Process Automation Processor Board

Honeywell 51403299-100 LCNP4 Process Automation Processor Board


Only 10 left - Selling fast

PRODUCT SKU : 51403299-100

PRODUCT TYPE : Processor Board

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51403299-100 acts as a high-throughput LCNP4 processor board within the Honeywell Distributed Control Systems (DCS) architecture. This board drives the core communication link between individual process controllers and the main Local Control Network (LCN). We supply this product as a 100% brand new, factory-original component, ensuring uninterrupted data traffic and precise time-synchronization across your process automation infrastructure.

Technical Specifications

Parameter Specification
Brand / Manufacturer Honeywell
Model Number 51403299-100
Board Type Processor Board (LCNP4)
Processor Technology LCNP4 with integrated GPS support
Physical Dimensions $3.7 \times 2.7 \times 0.7\text{ inches}$ ($9.4 \times 6.9 \times 1.8\text{ cm}$)
Net Weight 0.2 lbs (0.09 kg)
Operating Temperature Range 0 °C to +50 °C
Storage Temperature Limits -40 °C to +70 °C
System Framework Honeywell Distributed Control Systems (DCS)
Product Condition 100% Brand New Original

Engineering Advantages

  • Precise Plant-Wide Clock Synchronization: The integrated GPS hardware support allows this processor card to execute ultra-precise time stamping across the control network. This feature resolves chronological discrepancies between disparate data logs during root-cause sequence event analysis.

  • Ultra-Compact Footprint for Dense Racks: The card measures just $3.7 \times 2.7 \times 0.7\text{ inches}$. This miniature design allows control engineers to insert the module into tightly packed, low-profile chassis slots, maximizing total network processing power per square inch of cabinet space.

  • Negligible Mechanical Backplane Strain: Weighing a mere 0.2 lbs (0.09 kg), this lightweight component puts virtually zero mechanical load on delicate backplane connectors. This featherweight construction eliminates pin fatigue and micro-cracks caused by low-frequency plant vibrations.

FAQs

  • What specific function does the GPS support provide on the 51403299-100 processor board?

    The GPS capability allows the LCNP4 board to lock onto global time signals. This function synchronizes your local controllers with the master DCS clock, ensuring uniform execution of time-critical automation sequences.

  • Can this card withstand high-temperature unventilated field enclosures?

    The board operates continuously within a range of 0 °C to +50 °C. For environments exceeding +50 °C, you must provide active cabinet cooling or fan filtration units to prevent heat saturation on the LCNP4 silicon components.

  • Does this product arrive in original Honeywell anti-static packaging?

    Yes. We ship every Honeywell 51403299-100 unit as 100% brand new, sealed directly within factory-original ESD protective shielding to guarantee total hardware integrity upon delivery.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more