Product Details

Product Overview

The Honeywell 51401551-300 functions as a high-performance, high-density K2LCN-3 processor board within the legacy TDC 3000 Distributed Control System (DCS) ecosystem. This processing module executes advanced control algorithms, coordinates localized data distribution, and manages fast node communication across the Local Control Network (LCN). We provide this component exclusively in 100% Brand New, original factory-sealed condition to maximize computational performance and prevent unplanned loop downtime in critical chemical, refining, and power generation plants.

Technical Specifications

Parameter Product Technical Specification
Part Number 51401551-300
Manufacturer Honeywell
Series Architecture TDC 3000 DCS
Board Generation / Type K2LCN-3 High Performance / High Density
Functional Category Processor Board / PC Board PLC Add-On
Physical Weight 2.16 lbs (0.98 kg)
Form Factor Standard Rack/Chassis Mounting Slot
Condition 100% Brand New Original

Engineering Advantages

  • Elevates Processing Density: The advanced K2LCN-3 architecture integrates denser integrated circuitry onto a single PCB footprint. This compact hardware design consolidates system memory and clock speed, allowing a single slot to manage complex calculations that previously required multiple vintage cards.

  • Neutralizes High-Speed Signal Cross-Talk: Multi-layer board construction insulates data buses against electrical noise and cross-talk during heavy network traffic bursts. This layout protects system logic execution from erratic failures caused by localized EMI fields inside crowded automation cabinets.

  • Accelerates System Upgrades: The physical architecture fits standard, native TDC 3000 chassis slots without modifying the backplane layout. Engineers slide the 2.16 lbs card directly into the rack, securing the integrated retention screws to establish immediate grounding and power connections.

  • Reduces Total Cabinet Power Draw: Despite the increased computational throughput, the modernized silicon componentry draws less current per cycle than standard legacy processors, minimizing thermal buildup inside completely enclosed, unventilated field control stations.

FAQs

  • What specific software version or revision does the K2LCN-3 51401551-300 board require?

    This high-performance processor card requires specific Honeywell TDC 3000 system software releases that recognize the K2LCN-3 node architecture. Verify your local system configuration files and software licensing parameters prior to slotting this card into production.

  • Does this brand-new card feature pre-loaded system firmware?

    The board arrives with factory-flashed base firmware to initiate standard LCN hardware handshakes. Your engineers must complete final node personality loading and network configuration through the standard TDC 3000 engineering terminal upon initial power-up.

  • What handling steps prevent accidental component failure before installation?

    Keep the processor board inside its factory static-shielding bag until the exact moment of installation. Technicians must wear a calibrated electrostatic discharge (ESD) wrist strap connected to the cabinet frame during handling to prevent high-voltage static puncturing the high-density microprocessors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more