Skip to content

What are you looking for?


You may also like

Honeywell 51304907-200 TDC 3000 Process Communication ModuleHoneywell 51304907-200 TDC 3000 Process Communication ModuleHoneywell 51304907-200 TDC 3000 Process Communication Module
Honeywell 51304907-200 TDC 3000 Process Communication Module
Honeywell 51304907-200 TDC 3000 Process Communication Module
Honeywell 51304907-200 TDC 3000 Process Communication Module

Honeywell 51304907-200 TDC 3000 Process Communication Module


Only 10 left - Selling fast

PRODUCT SKU : 51304907-200

PRODUCT TYPE : Process Communication Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51304907-200 functions as a high-reliability process communication module within the TDC 3000 automation architecture. This module establishes secure, deterministic data bridges between legacy control networks and modern Ethernet-based plant management systems. We supply this product in 100% brand new, original factory-sealed condition to guarantee optimal field lifecycle and compliance with strict industrial standards.

Technical Specifications

Parameter Specification
Power Supply 120/240 VAC, 50/60 Hz, 0.35A
Communication Ports 1 x Ethernet 10/100Base-T, 1 x RS-232, 1 x USB 2.0
Security Protocols 128-bit AES encryption, WPA/WPA2, MAC address filtering
Battery Backup 3 x AA alkaline batteries (not included)
Operating Temperature -20°C to 60°C (-4°F to 140°F)
Storage Temperature -40°C to 70°C (-40°F to 158°F)
Relative Humidity 0 to 95% (non-condensing)
Dimensions (W x H x D) 70mm x 124mm x 31mm (2.76" x 4.88" x 1.24")
Net Weight 0.16 kg (0.35 lbs)

Engineering Advantages

  • Mitigates Cyber Risks: The onboard 128-bit AES encryption and MAC address filtering block unauthorized network intrusions at the hardware level, protecting critical process loops from malicious data injection.

  • Survives Harsh Substation Environments: The ruggedized internal circuitry withstands extreme thermal swings from -20°C to 60°C, preventing signal drift and communication dropouts in unconditioned field enclosures.

  • Eliminates Data Loss During Outages: The triple AA battery backup system preserves volatile memory configurations and communication logs instantly during primary AC power interruptions.

  • Simplifies Compact DIN-Rail Deployment: The ultra-compact 31mm profile minimizes cabinet footprint, allowing engineers to retrofit existing crowded marshalling panels without moving adjacent hardware.

FAQs

  • Does this module ship in pre-owned or refurbished condition?

    No. We sell this Honeywell 51304907-200 module exclusively as a 100% brand new, unused item in its original manufacturer packaging.

  • How does the module handle a complete loss of 240VAC main power?

    The module automatically draws power from the 3 x AA alkaline backup batteries. This prevents configuration loss and ensures immediate network re-initialization upon power restoration.

  • Can I use this module in high-humidity offshore applications?

    Yes, the module operates safely in environments with up to 95% relative humidity, provided the ambient atmosphere remains non-condensing and the enclosure matches the environment's NEMA/IP requirements.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more