Configured for real-time logic execution in control platforms, the Bachmann MPC293 (MPC293 CPU Module) provides direct processing and deterministic control within M1 system networks.

Hardware Specifications

Parameter Specification
Model MPC293
Brand Bachmann
Origin Austria
Dimensions Standard M1 module enclosure
Operating Temp Up to +60 deg C
Processor Type Embedded Pentium-class x86
Memory Scalable RAM / Mass storage
Interfaces Ethernet, USB, Serial, CAN, Fieldbus

Profinet / EtherNet/IP Deterministic Networks

The MPC293 architecture supports high-speed, deterministic control cycles required for complex industrial automation tasks. To maintain cycle-time consistency, the module utilizes the M1 system software environment that facilitates strict task scheduling across integrated communication interfaces. Firmware flash compatibility is managed via the M1 system stack, ensuring that protocol modules and I/O drivers remain synchronized with the processor core. Users must ensure that backplane bus communication velocity settings are correctly aligned with application requirements to prevent jitter or missed execution cycles within the deterministic control loop.

Frequently Asked Questions

Q: Does the MPC293 support field-installable memory expansion?

A: The MPC293 is designed with scalable memory options. Refer to the hardware configuration manual for specific module-compatible RAM and mass storage modules supported by the MPC293 series firmware.

Q: Is the module capable of managing multi-role tasks such as PLC and motion control simultaneously?

A: The Bachmann M1 system software allows the MPC293 to concurrently execute PLC logic, motion control loops, and communication protocols within defined task priorities. Ensure CPU load thresholds are monitored to maintain deterministic timing.

Field Installation Guidelines

  1. Secure the module onto the DIN-rail or within the M1 rack, ensuring the mechanical locking mechanism is engaged for a robust ground connection to the chassis.
  2. Verify that the 24 VDC power supply is stable and filtered, as voltage fluctuations can impact the stability of the embedded x86 processor core.
  3. Utilize high-quality shielded cabling for Ethernet and CAN interfaces to prevent electromagnetic interference from impacting high-speed data transmission.
  4. Maintain sufficient vertical clearance around the module to allow for passive convection cooling, ensuring the operation remains within the rated limit of +60 deg C.
  5. Perform an initial system check by verifying the module status LEDs during boot-up to confirm successful M1 software initialization and network stack readiness.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more