Skip to content

What are you looking for?


You may also like

Allen Bradley 20D-DL2-ENET0 PowerFlex 700S DriveLogix 5730 ControllerAllen Bradley 20D-DL2-ENET0 PowerFlex 700S DriveLogix 5730 ControllerAllen Bradley 20D-DL2-ENET0 PowerFlex 700S DriveLogix 5730 Controller
Allen Bradley 20D-DL2-ENET0 PowerFlex 700S DriveLogix 5730 Controller
Allen Bradley 20D-DL2-ENET0 PowerFlex 700S DriveLogix 5730 Controller
Allen Bradley 20D-DL2-ENET0 PowerFlex 700S DriveLogix 5730 Controller

Allen Bradley 20D-DL2-ENET0 PowerFlex 700S DriveLogix 5730 Controller


Only 10 left - Selling fast

PRODUCT SKU : 20D-DL2-ENET0

PRODUCT TYPE : Controller

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen Bradley 20D-DL2-ENET0 functions as the high-performance computational core for the PowerFlex 700S drive system. As a DriveLogix 5730 controller, it merges powerful Logix-class programming with high-end motor control, allowing for distributed control architectures directly at the drive level. We supply this unit as 100% Brand New and Factory Original, providing a pristine, unpowered component to ensure the maximum operational lifespan of your critical power infrastructure.

Technical Specifications

The 20D-DL2-ENET0 handles complex motion logic and network synchronization via the following parameters:

Feature Specification
Product Line DriveLogix 5730 (PowerFlex 700S)
Rated Voltage 380‑480V AC
Phase Support 3-Phase
Communication Embedded EtherNet/IP
Enclosure Rating IP21
Operating Temp 0 °C to 40 °C
Humidity Range 5% to 80% (Non-Condensing)
Max Altitude 1000 Meters MSL (without derating)
UPC 820919372339

Engineering Advantages

  • Embedded EtherNet/IP Connectivity: This module integrates a native EtherNet/IP port, facilitating seamless data exchange between the drive and the enterprise network. It eliminates the need for external gateways, reducing both latency and the physical complexity of the control cabinet.

  • Localized Logic Execution: By hosting Logix-based control programs directly on the drive, this unit offloads processing tasks from the central PLC. This distributed intelligence minimizes network traffic and ensures that motion logic executes with the highest priority and timing precision.

  • 380-480V AC Compatibility: Designed for global industrial power standards, the internal circuitry manages voltage fluctuations across the 380-480V spectrum. This wide window ensures stable controller performance even in facilities with inconsistent grid quality.

  • Integrated IP21 Protection: The hardware features an IP21-rated enclosure, which protects sensitive internal electronics against vertical water drops and ingress from solid objects larger than 12.5mm. This allows for safe installation in standard industrial environments without requiring additional specialized shielding.

FAQs

  • Is this 20D-DL2-ENET0 unit 100% Brand New?

    Yes. Every 20D-DL2-ENET0 we supply is 100% Brand New and arrives in its original factory packaging. We do not sell used, refurbished, or "pull-out" hardware, guaranteeing zero-hour internal component wear.

  • Does this controller support multi-axis synchronization?

    Yes. Leveraging its embedded EtherNet/IP and Logix engine, the 20D-DL2-ENET0 coordinates with other DriveLogix or ControlLogix processors to manage complex, synchronized motion sequences across multiple PowerFlex drives.

  • What software do I need to configure the 20D-DL2-ENET0?

    You must use the Studio 5000 Logix Designer (or RSLogix 5000 for older revisions) software environment. This allows you to develop ladder logic or structured text programs that execute natively on the DriveLogix 5730 hardware.

  • Can I mount this module in an outdoor enclosure?

    The unit carries an IP21 rating and an operating limit of 40 °C. For outdoor applications, you must install the unit within a NEMA 4/4X or IP66 rated enclosure with appropriate thermal management (fans or heat exchangers) to maintain the required environment.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more