Product Overview

The Allen-Bradley 2080-LC70-24QWB serves as a powerful and flexible Ethernet/IP controller within the Micro870 product line. Designed for small to mid-sized standalone machines, this programmable logic controller (PLC) features 24 built-in I/O points (14 inputs and 10 relay outputs) and 128 KB of memory. It offers versatile connectivity with native Ethernet/IP, Modbus RTU, and serial communication ports, allowing seamless integration into diverse industrial networks. We supply this item as a 100% Brand New, factory-sealed unit.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley (Rockwell Automation)
Product Line Micro870
Product Type Ethernet/IP Controller (PLC)
Total I/O Points 24 (14 Inputs / 10 Outputs)
Output Type Relay
Input Voltage 12 / 24 Volts DC
Memory Space 128 KB
Communication Ports Ethernet/IP, RS485/RS232
Communication Features Modbus RTU Master/Slave
Operating Temperature -20°C to 65°C
Weight 3.00 lbs (1.36 kg)

Engineering Advantages

Advanced Communication and Connectivity
The 2080-LC70-24QWB excels in machine connectivity with its native Ethernet/IP port and built-in RS485/RS232 serial interface. Engineers can easily configure the controller as a Modbus RTU master or slave, allowing direct communication with VFDs, HMIs, and third-party devices without requiring expensive additional communication modules.

Robust Relay Output for Direct Load Control
Featuring 10 built-in relay outputs, this controller can directly switch higher voltage AC or DC loads, such as motor starters, solenoids, and indicator lights. This eliminates the need for external interface relays in many applications, significantly reducing panel space, wiring complexity, and overall bill of materials costs.

Wide Operating Temperature Range
Built to withstand harsh industrial environments, the Micro870 controller operates reliably in ambient temperatures ranging from -20°C to 65°C. This wide thermal tolerance ensures stable performance in unconditioned machine enclosures, outdoor cabinets, and demanding manufacturing processes where standard commercial electronics would fail.

FAQs

Q: How many I/O points are built into the 2080-LC70-24QWB?
A: This controller comes with 24 built-in I/O points, specifically configured as 14 digital inputs and 10 relay outputs, providing a solid foundation for machine control without immediate expansion needs.

Q: What communication protocols does this Micro870 controller support?
A: It features a native Ethernet/IP port for seamless integration with Rockwell Automation ecosystems. Additionally, the RS485/RS232 port supports Modbus RTU master/slave protocols for connecting to a wide variety of third-party industrial devices.

Q: What type of outputs does the 2080-LC70-24QWB use?
A: The controller uses relay outputs. Relays are highly versatile as they can switch both AC and DC loads, making them ideal for controlling devices like contactors, lamps, and small motors directly.

Q: What is the operating temperature range for this PLC?
A: The 2080-LC70-24QWB is rated for an operating temperature range of -20°C to 65°C, ensuring dependable performance in challenging environmental conditions commonly found in industrial settings.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Understanding Marshalling Cabinets in Industrial Control Systems Architecture

Industrial control system deployments rely on structured signal distribution to bridge field instrumentation with central processing hardware. A marshalling cabinet serves as the vital intermediate connection point between heavy field home-run multi-pair cables and delicate input/output (I/O) modules housed inside Programmable Logic Controller (PLC) or Distributed Control System (DCS) enclosures. By segregating field cable terminations from control hardware, engineers maintain system flexibility, safeguard controller components, and streamline commissioning workflows.

Read more
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more